Section 2
Installation
Quick Setup
and Use Guide
Input cable connection (enclose installing diagram)
1. Every machine has been supplied with the relevant voltage connecting plug.
The power cable must be connected to the correct power source for either plug:
11Ov uses pigtail adaptor plug supplies, 220v uses plug already attached on
power cord end. If the Plasma Cutter is connected to a 220v Power source using a
11Ov plug or if the 220v power plug is connected to 11Ovthis may cause damage
to the unit.
2. Make sure power cable is connected to power receptacle securely, to eliminate
any arcing or oxidization.
3. Do not operate on a generator that does not have a clean sine wave and stable
power output. Spiking on voltage output can cause damage to components in the
Plasma cutter.
Output cable connection
1. Air input line needs to be securely pushed into the quick connect fitting so as to
prevent any air leaks.
2. Connect the plasma torch central connector to the output terminal on the front
panel using your hands.
Do not over tighten the connection as it can cause damage.
3. Finally connect the work lead (Ground clamp) connection to the black dinse
connection.
CHECK
1. Check if the plasma cutter is grounded reliably according to local standards. If
used on standard breaker panel box the ground wire and panel should be already
grounded according to your local code.
2. Check if all connectors are firmly connected.
3. Check if power voltage is correct.