525928 Instruction AC-reactor FS16-55 RS27-35 P9/15
1-ph inverter (standard version):
Disconnect the 2 wires (normally black and blue)
from the inverter contactor (CFI) that come from
the mainswitch.
3-ph inverter (3x380-480V without N only):
Disconnect the 3 wires (normally black) from the
inverter contactor (CFI) that come from the
mainswitch.
1-ph inverter :
Connect these wires to terminals U1 and V1 of
the AC-reactor.
3-ph inverter :
Connect these wires to terminals U1, V1 and W1
of the AC-reactor.
1-ph inverter :
Connect terminals U2 and V2 to the inverter
contactor by new wires, to the same terminals
where you have disconnected the 2 other wires.
Terminals W1 and W2 of the AC-reactor will not
be used if the inverter is 1-phase.
3-ph inverter :
Connect terminals U2,V2,W2 to the inverter
contactor by new wires, to the same terminals
where you have disconnected the 3 other wires
Make sure to attach and connect all wirings so
that they can not be damaged.