26 INSTALLATION AND MAINTENANCE MANUAL PUBLICATION DATE 07/04 513289
WARNING !
STOP THE HOT WATER INLET TO THE MACHINE AND WAIT UNTIL THE COMPONENTS COOL DOWN!
– shut the main water inlet, take off the inlet valve filters, clean and put them back.
A damaged hose:
– replace the hose or its gasket.
Defective inlet valve:
– change the valve.
Water escaping:
check the inlet pipeline, hoses, valves, filters, tapes, clamps, their connections and eliminate possible leakage.
6.3. TOO LONG HEATING TIME
Insufficient steam supply:
– too many steam-heated machines connected
– leakage of the steam system
– too high level of condensation in the steam system
Clogged steam filter:
WARNING !
STOP THE STEAM INLET TO THE MACHINE AND WAIT UNTIL THE COMPONENTS COOL DOWN!
dismantle the sieve, fig.5.10. pos.2) from the filter body (1), clean the sieve and put it back with the gasket (3)
Defective steam or hot water valve:
– exchange the valve
6.4. TOO LONG DRAINAGE TIME
Clogged drainage:
– clean the outlet.
Defected drainage valve:
– clean the drainage valve or exchange defected parts
Too small waste sump dimensions:
– check the waste sump diameters and enlarge it accordingly
6.5. PROGRAMMER PROBLEMS
See the chapter „Troubleshooting“ in the „Programming manual“.
!
!