Machine cleaning
Clean the filter components regularly, because the mites in the absorbed cotton wool
may not be killed, and will continue to reproduce. In order to avoid secondary pollution,
the filter components should be cleaned, or replace the new filter components after
cleaning.
1. Close the machine
2. Grasp the machine handle with the right hand and the other hand press the dust cup
down to remove the lock and rotate the dust cup clockwise. When the dust cup rotates
clockwise, pull out the dust cup down.
Press down
3. Hold the dust cup, press the arrow to take out the wind, press the open button to open
the bottom cover of the dust cup to clean up the dust.Lift the filter hand and rotate the
arrow clockwise to hear the click, take the filter button head down, rotate the cyclone cone
counterclockwise out of the card slot, take the cyclone cone in the arrow direction upward,
clean the dust, can rinse the filter components with water, filter element, dry.
Air inlet Hepa
Dust cup empty
buttom
Cyclone cone
filter
Cyclone cone filter lift
handle
Stainless steel mesh
filter