4.2.3 Frequency
Measuring range
Resolution
Accuracy
9.999Hz
0.001Hz
± (1.5%Reading +5 digits)
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999KHz
0.001KHz
99.99KHz
0.01KHz
999.9KHz
0.1KHz
9.999MHz
0.001MHz
Input voltage range: 200mV-10V AC valid value.
Overload protection: 250V DC/AC
4.2.4 Duty Cycle
Measuring range
Resolution
Accuracy
1%~99%
0.1%
± (2.5%Reading +5 digits)
Input voltage range: 200mV-10V AC valid value.
Overload protection: 250V DC/AC
4.2.5 Capacitor
Measuring range
Resolution
Accuracy
60nF
0.01nF
± (4%Reading +5 digits)
600nF
0.1nF
6μF
0.001μF
60μF
0.01μF
600μF
0.1μF
6mF
0.001mF
100 mF
0.01mF
± (4%Reading +10 digits)
Overload protection: 250V DC/AC
4.2.6 Electric resistance
Measuring range
Resolution
Accuracy
600
0.1
±(0.8% Reading + 5 digits)
6k
1
60k
10
600k
100
6M
1k
60M
10k
Overload protection: 250V DC/AC