EasyManuals Logo

Pro1 IAQ T731W User Manual

Pro1 IAQ T731W
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
T731W(O)
Installation Manual
Pro1 Technologies
Toll Free : 888-776-1427
Web: www.pro1iaq.com
Hours of Operation: M-F 9AM - 6PM Eastern
Thermostat Application Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Electric Aux.)
Multi-Stage Systems
Heat Only Systems - Floor or Wall Furnace
Cool Only Systems
Millivolt
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Power Type
Battery Power
Hardwire (Common Wire)
Hardwire (Common Wire) with
Battery Backup
Table of Contents
Installation Tips
Thermostat Quick Reference
Base Module Mounting Tips
Wiring
Technician Setup
Establishing Communication
Network Specications
Specications
Page
A trained, experienced
technician must install this
product.
Carefully read these
instructions. You could damage
this product or cause a
hazardous condition if you fail
to follow these instructions.
Una version en español de este
manual se puede descargar en
la pagina web de la compañia.
Rev. 2010
Mount Thermostat
Align the 4 tabs on the subbase
with corresponding slots on the
back of the thermostat, then push
gently until the thermostat snaps
in place.
Battery Installation
Battery installation is
optional if thermostat is
hardwired (R and C terminal
connected to 24V power).
Important:
High quality alkaline batteries are recommended.
Rechargeable batteries or low quality batteries
do not guarantee a 1-year life span.
Insert 2 AA
Alkaline batteries
(included). High
quality alkaline
batteries are
recommended.
Installation Tips
2
4-5
8-11
12-16
1
2-3
Installation Tips Thermostat Quick Reference
Getting to know your thermostat
3
4
Subbase Installation
The thermostat should be installed approximately 4 to 5 feet above the
oor. Select an area with average temperature and good air circulation.
• Close to hot or cold air ducts
That are in direct sunlight
With an outside wall behind
the thermostat
• In areas that do not require
conditioning
Where there are dead spots
or drafts
(in corners or behind doors)
Where there might be
concealed chimneys or
pipes
Wall Locations
Vertical Mount
Horizontal Mount
For vertical mount put one screw on the top
and one screw on the bottom.
For horizontal mount put one screw on the
left and one screw on the right.
All of our products are mercury free.
However, if the product you are
replacing contains mercury, dispose of
it properly. Your local waste
management authority can give you
instructions on recycling and proper
disposal.
Pick an installation location that is easy for
the user to access. The temperature of the
location should be representative of the
building.
Installation Tip
Mercury Notice
Do not install
thermostat in locations:
Failure to disconnect the power before
beginning to install this product can
cause electrical shock or equipment
damage.
Installation Tip:
Electrical Hazard
U.S. Registered Trademark. Patents pending
Copyright 2020 All Rights Reserved.
Heat Pump (With Gas Aux.)
Emergency Heat
Conventional Single Stage Furnace
Geothermal
High, Medium and Low Fan Speed
No
No
Yes
Yes
19
Located on the back of thermostat.
P.O. Box 3377
Springeld, MO 65808-3377
Glow in the Dark Light Button
Setpoint Buttons
LCD
System Button
Fan Button
R
17-18
20
6-7
Occupancy Sensor
(Occupancy Model Only)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pro1 IAQ T731W and is the answer not in the manual?

Pro1 IAQ T731W Specifications

Temperature IconTemperature
temperature display range41˚F to 95˚F (5˚C to 35˚C)
temperature control range44˚F to 90˚F (7˚C to 32˚C)
heating swing adjustment0.2˚ to 2.0˚
cooling swing adjustment0.2˚ to 2.0˚
Power IconPower
thermostat power source18 to 30 VAC, NEC Class II, 50/60 Hz
thermostat battery power2 AA Alkaline batteries
base module power source18 to 30 VAC, NEC Class II, 50/60 Hz
Operating Environment IconOperating Environment
thermostat operating ambient temperature32˚F to +105˚F (0˚C to +41˚C)
base module operating ambient temperature32˚F to +150˚F (0˚C to +65˚C)
operating humidity90% non-condensing maximum
Load Rating IconLoad Rating
thermostat load rating per terminal1 amp
thermostat maximum load rating all terminals combined1.5 amp
base module load rating per terminal1 amp
base module maximum load rating all terminals combined1.5 amp
Dimensions and Frequency IconDimensions and Frequency
dimensions of thermostat4.7”W x 4.4”H x 1.1”D
frequency916 MHz

Related product manuals