22
21
23
Programming Programming
Specications
Set Program Schedule 5+1+1 or 7 Day
1. Select HEAT or COOL with the system switch. Note: You have
to program heat and cool each seperately.
2. Press the MENU button (If menu does not appear rst press RUN SCHED)
3. Press SET SCHED. Note: Monday-Friday or (Monday if in 7 Day)
is displayed and the WAKE icon is shown. You are now
programming the wake time period for that day.
4. Time is ashing. Use the or key to make your time
selection for that day’s WAKE time period. Note: If you want
the fan to run continuously during this time period, select ON
with the FAN key
5. Press NEXT STEP
6. The setpoint temperature is ashing. Use the or key
to make your setpoint selection for that day’s WAKE time
period.
7. Press NEXT STEP
8. Repeat steps 4 thru 7 for that day’s LEAVE time period,
RETURN time period, and SLEEP time period.
To customize your program schedule, follow these steps:
You can use the table below to plan your customized program schedule.
Repeat steps 4 thru 8 for the Saturday + Sunday time
periods.
If in 5+1+1 Programming:
Use these same steps for every individual day.
If using 7- Day Programming:
Specications
The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)
The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)
Load Rating............................................... 1 amp per terminal, 1.5 amp
maximum all terminals combined
Swing (cycle rate or dierential) ...... Heating is adjustable from 0.2˚ to 2.0˚
Cooling is adjustable from 0.2˚ to 2.0˚
Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz
for hardwire
Battery power from 2 AA Alkaline
batteries
Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)
Operating humidity .............................. 90% non-condensing maximum
Dimensions of thermostat ................. 4.7” W x 4.3” H x 0.9” D