Page #13 background imageLoading...
Page #13 background image
13 © 2017 Proceq SA
E
Center Line (CL)
*When an Arrow LED lights up move the
probe along the rebar axis until MC LED
C
or
D
lights up. Then the MC is
precisely above a rebar axis.
By pushing
A
and
B
simultane-
ously the cursor jumps to the next line
(in Multi-Line, Area-Scan and Cross-Line
Mode only)
B
Short: Measure diameter
Long: Zeroing
D
Measurement Center when
Spot range is set (MC Sp)
Measurement Center when Standard,
Large or Auto range is set (MC SLA)
Short: Start / Stop
Long: Set marker
A
C
F
Arrow LED indicates proximity of rebar*
Arrow LED indicates proximity of rebar*
F
Figure 6: Universal Probe overview

Questions and Answers: