Questions and Answers

  • M
    Marcia DavisAug 14, 2025
    Why is my Prochem Floor Machine losing vacuum?
    • L
      lauren50Aug 15, 2025
      A loss of vacuum in your Prochem Floor Machine can stem from several issues. The vacuum gauge might be giving an improper reading due to a blockage in the tubing, or the vacuum hose could be damaged, causing a suction leak. Other potential causes include waste tank gaskets not sealing properly, a plugged vacuum hose or plumbing, a plugged waste tank filter or strainer basket, loose vacuum pump drive belts, a damaged or open waste tank drain valve causing a vacuum leak, a vacuum relief valve needing adjustment or having a damaged diaphragm, vacuum exhaust heat exchangers plugged with lint, or a worn-out vacuum pump. Inspect these components to identify and resolve the issue.
  • S
    Stephanie MurrayAug 18, 2025
    Why won't my Prochem EVEREST LP engine start?
    • K
      Kristen ThomasAug 18, 2025
      If your Prochem Floor Machine's engine won't start, several factors could be at play. The main circuit breaker on the control panel might have tripped, or there could be a loose or corroded battery connection. A dead battery, a defective ignition switch, or a defective starter motor could also be the cause. In rare cases, the vacuum pump might be seized. Check these components to diagnose the issue.
  • S
    Stephanie WalshAug 21, 2025
    What to do if Prochem EVEREST LP Floor Machine starter turns over but doesn't start?
    • L
      Leslie PittsAug 21, 2025
      If the starter in your Prochem Floor Machine turns over the engine but it won't start, the waste tank might be full. The engine temperature may have exceeded 240°F, triggering the high-temperature switch. Other possible causes include a defective fuel pump, loose or broken wires leading to the waste tank float switch, or a defective float switch in the waste tank. Additionally, the oil pressure switch, anti-diesel solenoid, or high-temperature switch located on the engine might be defective. Check these components to resolve the starting issue.
  • R
    Ryan SmithAug 25, 2025
    How do I troubleshoot loss of solution volume in Prochem EVEREST LP Floor Machine?
    • K
      kristinapageAug 25, 2025
      A loss of solution volume at the cleaning tool orifice in your Prochem Floor Machine can be due to a plugged orifice or screen in the cleaning tool. There may be an internal block between the pressure regulator manifold and the outlet Y-strainer, or the Y-strainer screen could be clogged. Other causes may include a plugged outlet check valve, a defective quick-connect on the high-pressure hoses, a malfunctioning cleaning tool valve, or a constricted hose inner lining. Inspect these areas to identify and fix the problem.
  • R
    Richard YorkAug 27, 2025
    What causes the water pump to not engage on my Prochem EVEREST LP?
    • V
      Vincent StewartAug 28, 2025
      If the water pump on your Prochem Floor Machine doesn't engage, the solution pump circuit breaker may have tripped; check the breaker on the control panel and reset it. There could be a defective electrical connection or switch. The water pump might not be activated, so ensure the solution pump switch is on. A defective water pump clutch or loose/broken water pump belts could also be responsible. Examine these components to determine the cause.
  • T
    Timothy MartinezAug 31, 2025
    Why is my Prochem EVEREST LP losing chemical?
    • C
      Christie MaxwellAug 31, 2025
      A loss of chemical in your Prochem Floor Machine could be due to several reasons. The chemical pump might be improperly primed, or the strainer at the inlet end of the chemical inlet line could be clogged. A suction leak in the inlet line leading into the chemical pump, clogged chemical pump check valve(s), a defective chemical prime/on-off valve or metering valve, or a ruptured chemical pump diaphragm could also be responsible. In some cases, a defective cylinder in the water pump might be the cause. Check these components to identify the issue.
  • K
    kathryn11Sep 4, 2025
    Why is the automatic waste pump malfunctioning on my Prochem EVEREST LP Floor Machine?
    • T
      Tammy SantosSep 4, 2025
      If the automatic waste pump in your Prochem Floor Machine is malfunctioning, it could be due to a defective waste pump float switch or a broken diaphragm. A weak battery or a tripped pump-out circuit breaker on the control panel could also be the cause. Inspect these components to diagnose and fix the issue.
  • M
    Maria DudleySep 7, 2025
    What causes excessive heating in a Prochem EVEREST LP?
    • C
      Christopher FlowersSep 7, 2025
      Excessive heating in your Prochem Floor Machine could be caused by a flow restriction due to hard water scaling. Descale the unit, repair or replace any damaged plumbing components, and consider installing a water softener. Another cause may be insufficient water flow; check the jet size of the tool.
  • M
    Michael GarzaSep 10, 2025
    What causes loss of temperature in Prochem EVEREST LP Floor Machine?
    • R
      Rhonda SmithSep 10, 2025
      A loss of temperature in your Prochem Floor Machine can occur if the temperature relief valve on the water box is stuck open; clean and test the valve, replacing it if necessary. Low engine RPM or a defective temperature gauge could also be the cause. Reset the engine RPM or test the gauge and sensor, replacing any failed components.