32 PRODIGIT
MEASURE COMMAND
COMMAND
331XF
333XF
334XF/G
33401F/G
RETURN
MEASCURR {?}{NL}
V V V V ###.####
MEASVOLT {?}{NL}
V V V V ###.####
MEASPOW {?}{NL}
V V V ###.####
MEASVC {?}{NL}
V V V V ###.####,###.####
TABLE 4-7 MEASURE COMMAND SUMMARY
COMMAND
331XF
333XF
334XF/G
33401F/G
RETURN
GLOBPRES{SP}{ONOFF10}{NL}
V V
GLOBLOAD{SP}{ONOFF10}{NL}
V V V V
GLOBMODE{SP}{CCCRCVCP}{
NL}
V V V (*9)
GLOBMODE{SP}{CCCRCVCPLED}{
NL}
V (*9)
GLOBMODE{SP}{CCCRCVLED}{
NL}
V V (*9)
GLOBSHOR{SP}{ ONOFF10}{NL}
V V V (*9)
GLOBDYN{SP}{ONOFF10}{NL}
V V V (*9)
GLOBLEV{SP}{HIGHLOW10}{NL}
V V V (*9)
GLOBRANG{SP}{ LOWHIGH12}{
NL}
V V V V (*9)
GLOBMEASCURR{?}{NL}
V V V V ###.##
GLOBMEASVOLT{?}{NL}
V V V V ###.##
TABLE 4-8 GLOBE COMMAND SUMMARY
REMARK:
1. Frequency engineering unit: Hz
2. GLOB: GLOBAL (all channels active in same time).
3. Current engineering unit: A
4. Voltage engineering unit: V
5. Resistance engineering unit: Ω
6. Period engineering unit: ms
7. Slew-rate engineering unit: A/us or mA/us
8. Power engineering unit: W
9. *9 CR DYN function version of the following
a. 3302F at r2.15 version above is enabled
b. 3310F at r1.11 version above is enabled
c. 3311F at r1.11 version above is enabled.
d. 3312F at r1.11 version above is enabled.
e. 3314F at r1.11 version above is enabled.
f. 3315F at r1.11 version above is enabled.