WARNING:
Under no circumstances should you immerse
the device in water for cleaning purposes.
Otherwise this might result in an electric shock
or re.
CAUTION:
Do not use a wire brush or any abrasive items
.
Do not use any acidic or abrasive detergents.
CERAN
®
-Glass ceramic Hob
Clean the surface from food remains when it‘s
still warm using a moist cloth or tissue.
Wash the hob using a soft sponge and some
water, then wipe dry with a soft cloth.
Cleaning agent for glass-ceramics surfaces:
In case of stubborn, baked-in remains, use
suitable cleaning products available at special
departments of department stores.
Housing
Clean the housing after use using a slightly
moist cloth.
Make sure that no uid matter gets into any of
the openings of the housing. This might dam-
age the device or result in an electric shock.
Storage
Only store the appliance clean and after it has
cooled down.
During longer periods of non-use we recom-
mend storing the appliance in its original
packaging.
Always store the appliance in a well-ventilated
and dry place out of reach of children.
CAUTION: Risk of breakage!
Please remember that the CERAN
®
surface can
be damaged by heavy or falling objects.
Troubleshooting
Device does not function, no indication on
the display.
Remedy:
Check the mains connection.
Several warnings will sound after the ap-
pliance has been turned on and after the
cooking function has been selected
Possible cause:
No cookware or unsuitable cookware was
placed onto the plate.
NOTE:
For safety reasons, the appliance will switch to
standby mode after about 15 seconds.
Remedy:
Put a pot on the hob that is suitable for induc-
tion hobs.
The hob suddenly switches off during
operation.
Possible cause:
The thermal cut-off is activated.
Remedy:
Disconnect the appliance from mains power
supply and let it cool down for approx. 20 min-
utes. Then start operating the device again.
Further cause:
The ventilation slots are obstructed.
Remedy:
Free the ventilation slots from any obstructions.
Further cause:
The hot plate was automatically switched off
after 120 minutes.