Chart above shows number of 100 pound tanks needed to operate heaters at a given temperature.
Less gas is vaporized at lower temperatures. You may need two or more 100 pound tanks, or one
larger tank in colder weather. Your local propane gas dealer will help you select the proper supply
system.
ProFitter
TM
Propane
Construction Heater
Operating Instructions & Parts Manual
LPFA40PF, RMC-FA60PF, RMC-FA125PF, and RMC-FA150PF
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
ProFitter
TM
Models LPFA40PF, RMC-FA60PF, RMC-
FA125PF, and RMC-FA150PF heaters are 30,000 to
150,000 BTU/Hr construction heaters. These heaters
use propane gas for combustion,
and electricity to run the fan.
It is primarily intended for temporary heating of well
ventilated buildings under construction, alteration or
repair.
Unpacking
1. Remove all packing items applied to heater for
shipment. Keep plastic cover caps attached to inlet
connector and hose/regulator assembly for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater
is damaged, promptly inform dealer where you
purchased the heater.
ELECTRICAL SPECIFICATIONS AND CAPACITY OF PROPANE GAS CYLINDERS
Electrical
Model Input Amperage Fan RPM Ignition Spark
LPFA40PF 120 V, 60 Hz .68 3550 Piezo/Manual Spark 0.16” (4.1 mm)
RMC-FA60PF 120 V, 60 Hz .65 3570 Continuous Spark 0.16” (4.1 mm)
RMC-FA125PF 120 V, 60 Hz .70 3580 Continuous Spark 0.16(4.1 mm)
RMC-FA150PF 120 V, 60 Hz .70 3580 Continuous Spark 0.11(2.8 mm
AND CAPACITY OF PROPANE GAS CYLINDERS
Specifications
GENERAL SPECIFICATIONS
Type of Minimum Manifold Gas Size
Model Gas Input Rating Pressure Pressure Consumption L x W x H (Inches)
LPFA40PF Propane 40,000 BTU/Hr 5 PSIG 11” W.C. 1.9 lbs/hr 0.86 kg/hr 19.3 x 8.3 x 13.5 (46 x 20.6 x 34.2 cm)
RMC-FA60PF Propane 30,000 to 60,000 BTU/Hr 5 PSIG 11” W.C. 1.4 - 2.8 lbs/hr 0.63 - 1.27 kg/hr 19.3 x 8.3 x 13.5 (46 x 20.6 x 34.2 cm)
RMC-FA125PF Propane 70,000 to 125,000 BTU/Hr 5 PSIG 11” W.C. 3.3 - 5.8 lbs/hr 1.5 - 2.09 kg/hr 25.6 x 12.7 x 15 (63.5 x 22.9 x 38.1 cm)
RMC-FA150PF Propane 120,000 to 150,000 BTU/Hr 5 PSIG 11” W.C. 5.6 - 7.0 lbs/hr 2.54 - 3.18 lb/hr 25.6 x 12.7 x 15 (63.5 x 22.9 x 38.1 cm)
Temperature Number of Tanks Needed
at Tank 40,000-60,000 BTU/Hr 125,000 BTU/Hr 150,000 BTU/Hr
32ºF (0ºC) 1 2 2
20ºF (-7ºC) 1 2 2
10ºF (-12ºC) 1 3 3
0ºF (-18ºC) 1 3 3
-10ºF (-23ºC) 2 Use Larger Tank Use Larger Tank
-20ºF (-29ºC) 2 Use Larger Tank Use Larger Tank
Table of Contents Page
Description ...................... 1
Specifications..................... 1
Unpacking ........................2
Product Features ...................2
General Safety Information ........ 2-3
Operation ......................3-4
Refilling the Propane Gas Tank . . . . . .3
Leak Checking and
Locating the Heater .............. 4
Lighting and Shutdown Instructions
.. 4
Test Firing Heater ................ 4
Wiring Diagrams .................5-6
Repair Parts List....................8
Repair Parts Illustration .............9
Troubleshooting Chart .............10
Warranty ........................10
Printed in China
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S
IMLPFPF - KIN
C US
ANS Z83.7-2017 CSA 2.14-2017
CONSTRUCTION HEATER