EasyManua.ls Logo

Profroid SUPERCOLD SCH - Page 41

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
/
61
c
CO
M
P
RE
SSO
R
P
A
R
AM
E
T
E
R
S
T
y
p
e
M
i
n
M
a
x
U
n
i
t
D
e
f
c
0
D
e
la
y
ti
m
e
be
t
w
e
e
n
t
h
e
r
e
g
u
la
t
o
r
st
a
r
t
-
up
a
nd
t
h
e
co
mp
r
e
s
s
o
r
s
t
a
r
t
-
up
C
0
15
m
in
3
c
1
D
e
la
y
b
e
t
w
ee
n
2
co
mpr
e
s
s
o
r
s
t
a
r
t
-
up
s
.
C
0
15
m
in
6
c
2
Co
mpr
e
s
s
o
r
m
i
n
i
m
a
l
s
t
o
p
d
e
la
y
.
C
0
15
m
in
0
c
3
Co
mpr
e
s
s
o
r
m
i
n
i
m
a
l
o
p
e
r
a
ti
n
g
t
i
m
e
.
C
0
15
m
in
0
c
4
Duty
setting
delay
(0=off,
100=on
).
s
ee
d
u
t
y
s
e
tt
ing
C
0
100
m
in
*
c
c
Co
n
ti
nu
o
u
s
c
y
cl
e
l
e
n
g
t
h
.
C
0
15
ho
urs
0
c
6
Ti
m
e
o
u
t
a
f
t
e
r
a
co
n
t
i
nu
o
u
s
c
y
cl
e
.
C
0
15
ho
urs
2
d
D
E
F
R
OS
T
C
Y
C
LE
P
A
R
AM
E
T
E
R
S
T
y
p
e
M
i
n
M
a
x
U
n
i
t
D
e
f
d
0
Type of defrosting: 0=electrical defrost,1=hot gas, 2=resistors with
operating time, 3= hot gas with operating time
C
0
3
F
la
g
0
d
l
I
n
t
e
r
v
a
l
b
e
t
w
e
e
n
t
w
o
d
e
fr
o
s
t
c
y
cl
e
s
S
0
199
Ho
urs
6
d
t
Te
m
p
e
r
a
t
ure
s
e
t
p
o
i
nt
t
o
e
nd
t
h
e
d
e
fr
os
t
c
y
cl
e
S
-
50
+199
°
C
/
°
F
7
d
P
M
a
xi
m
a
l
d
e
fr
o
s
t
c
y
cl
e
d
ur
a
ti
o
n
(o
r
st
a
n
da
rd
o
p
e
r
a
ti
n
g
ti
m
e
i
f
d
0
=2
o
r
3)
S
1
199
M
i
n
30
d
4
L
a
un
c
h
a
d
e
fr
o
s
t
c
y
cl
e
w
h
e
n
t
h
e
r
eg
u
l
a
t
o
r
i
s
s
t
a
r
t
i
n
g
-
up
(
0=n
o
,
1
=y
e
s
)
C
0
1
F
la
g
1
d
5
D
e
fr
os
t
c
y
cl
e
s
t
a
r
t
i
n
g
-
up
d
e
la
y
o
r
u
si
n
g
a
d
i
g
i
t
a
l
i
np
u
t
(A4
or
A5
=
4)
C
0
199
M
i
n
1
d
6
F
r
e
e
ze
t
h
e
d
i
s
p
la
y
d
ur
i
n
g
a
d
e
f
r
o
s
t
c
y
cl
e
(
0=n
o
,
1=y
e
s
)
C
0
1
F
la
g
1
d
d
D
r
a
i
n
i
ng
d
e
la
y
a
f
t
e
r
a
d
e
fr
os
t
c
y
cl
e
S
0
15
M
i
n
*
d
8
A
la
rm
te
m
p
o
r
is
a
ti
o
n
a
f
te
r
a
d
e
f
r
o
s
t
c
y
cl
e
,
i
f
A
4
o
r
A5
=
5
;
m
a
x
i
m
a
l
co
mpr
e
s
s
o
r
stop
delay
and
temperature
alarm
S
0
15
Ho
urs
1
d
9
D
e
fr
os
t
pr
i
o
r
i
t
y
o
ve
r
co
m
pr
e
ss
o
r
pr
o
te
c
ti
o
n
s
.
(
0=n
o
,
1=y
e
s
)
C
0
1
F
la
g
0
d
/
D
e
fr
os
t
pr
o
b
e
r
e
ad
i
n
g
S
-
-
°
C
/
°
F
-
d
C
Ti
m
e
b
a
s
e
(
0
=
h
o
ur
s
/
m
i
1
=
m
i
n
/
s
e
c
)
C
0
1
F
la
g
0
A
ALARM
M
A
N
A
G
EME
N
T
P
A
R
A
ME
T
E
R
S
T
y
p
e
M
i
n
M
a
x
U
n
i
t
D
e
f
A
0
A
la
rms
a
nd
cool
e
r
f
a
ns
d
i
f
f
e
r
e
n
ti
al
.
C
0
.
1
+20
°
C
/
°
F
4
AL
L
o
w
t
e
m
p
e
r
at
ure
ala
rm
(
m
i
n
i
m
a
l
v
a
r
i
at
i
o
n
allo
w
e
d
a
r
o
und
t
h
e
s
e
t
p
o
i
n
t
)
.
I
f
AL=0
this
alarm
is
disabled.
S
0
+199
°
C
/
°
F
*
AH
H
ig
h
t
e
mp
e
r
a
t
u
r
e
ala
rm
(
m
a
xi
m
a
l
v
a
r
i
a
ti
o
n
all
o
w
e
d
a
r
o
und
t
h
e
s
e
t
p
o
i
n
t
)
.
I
f
AH=0
this
alarm
is
disabled
S
0
+199
°
C
/
°
F
4
Ad
Te
m
p
e
r
a
t
ure
ala
rm
d
e
la
y
C
0
199
M
i
n
30
A4
D
ig
i
t
a
l
i
n
p
ut
I
D
1
co
nf
i
g
ur
at
i
o
n:
A4=0
disable
input
A4=1
external
alarm
non-delayed
(contact
opened
=alarm)
A4=2
external
alarm
delayed
(contact
opened=alarm:delay
A7)
A4=3
defrost
cycle
enable/disable
(contact
opened=defrost
cycle
is
disabled)
A4=4
defrost
cycle
begin
(contact
is
closing=
immediate
defrost
cycle)
A4=5
Door
switch
(contact
opened
=
door
opened.
When
the
door
is
openin
g
the
compressor
and
the
cooler
fans
stop).
If
H1=0,
the
AUX
output
is
enabl
e
(to
switch
the
light
on
for
example).
If
the
door
stays
opened
for
more
tha
n
the
value
configured
in
d8,
the
display
blinks
and
the
controller
restarts.
A4=6
remote
start/stop
(contact
closed=
start).
If
both
of
the
digital
inputs
ID1
and
ID2
are
selected
as
door
switches,
the
controller
is
switched
on
only
if
both
of
the
contacts
are
closed.
When
you
select
a
remote
start/stop,
the
ON/OFF
key
on
the
keypad
is
disabled.
A4=7 shutter contact (contact closed = shutter down). If, f
or
example, r4=3.0 (selected value), the set point is increase of 3
°C.
If the AUX output is used to control the lighting, when the contact i
s
switch off, the light is switched off, when the contact is switched
on,
the light is
switched
on.
C
0
7
-
0
A5
D
ig
i
t
a
l
i
n
p
ut
I
D
2
co
nf
i
g
ur
a
ti
o
see
A4
C
0
7
-
0
A6
A
c
tiv
a
t
e
t
h
e
cool
i
ng
d
i
g
it
a
l
o
u
t
p
ut
u
si
n
g
a
n
e
x
te
rn
a
l
ala
rm
(
0=
o
f
f,
100=
o
n
)
.
Allowed
if
A4
or
A5
=
1
or
2.
see
“duty
setting”
and
digital
input
C
0
100
M
i
n
0
A7
D
e
la
y
w
h
e
n
A4
o
r
A5
=2
(
e
x
te
r
n
a
l
ala
rm
d
e
la
y
e
d
)
C
0
199
M
i
n
0