3. Technical data
Cooling capacity* 2,500 watts
Energy efficiency* D (EER 2.62/COP -)
Air capacity 420 m
3
/h
Absorbed humidity 1.0 l/h
Timer 24 h
Operating voltage 220 - 240/50 V ~ Hz
Power rating: Cooling* 960 watts
Nominal power consumption, cooling 1,150 watts
Nominal current consumption, cooling 4.6 A
Compressor Rotary piston
Starting current 23 A
Outdoor temperature, cooling operation °C
+21 - +43 (DB)
Fluid line Ø A 6 mm
Suction pipe Ø A 9.52 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 407 C
Refrigerant filling capacity 500 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 37 dB (A)
Outside ≤ 52 dB (A)
Dimensions
Inside 71 x 25 x 18 cm
Outside 72 x 43 x 26 cm
Weight
Inside 7 kg
Outside 25 kg
* data in accordance with EN 14511
Note: SPLIT 850 C does not have a heating function.