Vantage SL Compact Troubleshoot Guide - Model #: SL1266
5
Problem
Cause
Action
Ref #
Power button on
digital controller face
is depressed but
doesn’t turn on.
1. Power cord is not plugged in.
2. Circuit breaker is tripped off in the
site's breaker box.
3. Transformer has taken an
electrical surge and is damaged.
4. Check voltage on the secondary
side of the Transformer. If you read
12VDC then you are receiving
voltage to the controller.
5. Possible blown fuse.
1. Plug the power cord into wall
receptacle and power button.
2. Reset circuit breaker that the
grill is plugged into. Depress
Power Button to turn on.
3. Replace Transformer after you
check secondary side of
transformer. If working properly,
you should receive 12vdc.
4. Replace controller. Controller
should be on once the power
button is depressed.
5. Replace fuse.
----
-----
18
A8
98
Digital controller's
LED's are scrambled
or randomly erratic.
If when turning on,
the display will first
go to segment check
1. Possibly a component on the
Digital controller is damaged.
2. Control needs to reset.
1. Replace digital controller.
2. While unit is on unplug unit,
wait for 1 min. Then plug machine
on again and depress the power
button.
A8
----