Appendix B. Wiegand Specification
Data Pulses
The Data One and Data Zero signals are normally held at a logic high level until the data is ready to be sent. Data is sent as below on
Data1 or Data0 lines. The following timing parameters shall be observed:
Data One
Data Zero
Tpw Tpw
Tpw TpiTpi
Voh
Voh
Vol
Vol
Tpw Pulse Width Time -- 20µSec (minimum) to 100µSec (maximum)
Tpi Pulse Interval Time -- 200µSec (minimum) to 20mSec (maximum)
Wiegand interface (26-bit format):
Summed for even parity (E)
Summed for odd parity (O)
Wiegand interface (30-bit format):
Summed for even parity (E)
Summed for odd parity (O)
Wiegand interface (34-bit format):
Summed for even parity (E)
Summed for odd parity (O)