INVERTER SPECIFICATIONS:
Output Power Continuous: 400W
Low Battery Shut Down: DC 9V ± 0.3V
Output Power Surge: 800W
Frequency: 60 Hz ± 3
Operating Voltage: DC 11-14.5V
Efficiency: 85%
AC Output Voltage (RMS Meter): 220V ±10%
No Load Current Draw: < 0.65A
Output Wave Form: Filtered Modified Sine Wave
Over Temperature Protection: 100°C ±10%
Low Battery Alarm: DC 10.3V ± 0.3V
LOCATION OF CONTROLS
5. Solar charging port
6. 2 x 12V DC jack
7. 12V DC socket
8. 3 x USB port
9. Power inverter ON / OFF switch
10. USB power ON / OFF switch
III. CHARGING THE
POWERSTATION
NOTE: Powerstation must be fully charged for 16 hours before first use. Failure to do so may permanently damage battery.
TO READ THE POWERSTATION’S BATTERY VOLTAGE / INVERTER STATUS
1. Press the “ON” switch button of the power inverter
2. Press Display button to read the Power Inverter / Battery Voltage Status
“VAC” – Output AC Voltage
“Hz” - Output AC frequency
“Watt” - Power consumption of the device
“VDC”- Battery voltage of Powerstation
3. Recharge the unit when “VDC” reads < 12V
4. Switch Power inverter to “OFF” before recharging the unit.
CAUTION
This unit has a maintenance free, built-in sealed lead acid battery. Although the Promate240s arrives partially charged from the
factory, it must be fully charged for 16 hours before first use, even if the digital meter indicates “VDC” battery voltage >12.8V,
the battery is full. This initial charge pre-conditions of the battery are necessary. Failure to follow this procedure may
permanently damage the battery.