EasyManua.ls Logo

Prossimo PCF150WH - Trouble Shooting Guide

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trouble Shooting Guide
Trouble Possibilities Cheek up Solutions Remarks
The fuse is broken Check the fuse Replace the fuse
The connection
between plug and
socket is not good
Check the socket Repair or replace
the socket
Power is off
The circuit of input and
output is out of use
Make sure that
the power is on
Check the circuit with
electric instrument
If it is necessary
please contact
after-sales
service
for repair
Compressor
does not
work
The thermostat knob is not in the
proper position
Check the
thermostat
Rotate the
thermostat to the
proper position
Ask for
professional help
Frost on the
evaporator
is too thick
Check whether
the frost is thicker
than 6-8mm
Defrost regularly
The door is being
opened too frequently
Reduce the times
of opening
The
temperature
inside is too
high
Too much food has
been stored at once
Take out some of
the food
The ambient
temperature is too
high .while
the thermostat
indicates
a small number
Make sure
whether
the knob is
indicating at the
“5-6”(or deeper)
Adjust the
thermostat knob
The thermostat
knob on”2-4”is
better(or proper)
Compressor
keeps on
working
The
temperature
inside is OK
The thermostat does
not work
Replace the
thermostat
Ask for
after-sales
service
The floor is not level Make sure that
the freezer is
level
Put pad under the
castors
The screw in fan or condenser is loose The screw is
loose
Rotate the fixed
screw
Too noisy
The refrigerating circuits touch each
other
Separate them
7