Technical Specifications ProStar Operator’s Manual
69
68
7.0
Battery Charging Set-points (@ 25°C):
[multiply voltages by (2) for 24 Volt systems]
DIP
S
witch
S
ettings
4
-5-6
B
attery
T
ype
A
bsorp.
S
tage
(
volts)
F
loat
S
tage
(
volts)
E
qualize
S
tage
(
volts)
A
bsorp.
T
ime
(
mins)
E
qualize
T
ime
(
mins)
E
qualize
T
imeout
(
mins)
E
qualize
Equalize
Equalize
I
nterval
(
days)
Equalize
Interval
(days)
Equalize
Interval
(days)
off-off-off 1 - Sealed* 14.00 13.50
150
off-off-on 2 - Sealed* 14.15 13.50 14.40 150 60 120 28
off-on-off 3 - Sealed* 14.30 13.50 14.60 150 60 120 28
off-on-on 4- AGM/Flooded 14.40 13.50 15.10 180 120 180 28
on-off-off 5 - Flooded 14.60 13.50 15.30 180 120 180 28
on-off-on 6 - Flooded 14.70 13.50 15.40 180 180 240 28
on-on-off 7 - L-16 15.40 13.40 16.00 180 180 240 14
on-on-on 8 - Custom Custom Custom Custom Custom Custom Custom Custom
Custom Custom
Custom
* “Sealed” baery type includes gel and AGM baeries
Custom
LVD
(volts)
LVR
(volts)
Custom
12.30
13.80
12.10 13.60
11.90
13.40
11.50
13.00
11.70
13.20
11.30
12.80
11.50
12.60
Current Compensation:
12 Volt systems -20 mV/A
24 Volt systems -40 mV/A
Compensated set-points LVD, LVR
Compensation threshold 3A
Load and Solar Control:
[multiply voltages by (2) for 24 Volt systems]:
Default values (customizable)
LVD See table above
LVR See table above
Instant LVD 10.0V
HVD - load (@ 25ºC) 15.3V
HVD - solar (@ 25ºC) 15.2V
HVR - load (@ 25ºC) 14.5V
HVR - solar (@ 25ºC) 12.3V
LVD Warning 10 mins
LVD Override 10 mins
Maximum # LVD overrides No limit unless
(not customizable) V_batt < Instant LVD
Lighting Control (DIP 1 ON):
Lighting Timer Setting Dusk-Dawn (default)
Lighting Test Timer 5 mins
Data & Communications:
Communication Port MeterBus (RJ-11)
Comm. Protocols Morningstar MeterBus;
MODBUS
Data-logging 6-8 months, daily records
PC Software MSView
Digital Meter:
Resolution 128 x 64 pixels
Viewing Area 50 mm x 25 mm
Display Color blue on white
Backlight LED
Operating Temperature -20ºC to +70ºC
Storage Temperature -30ºC to +80ºC
Environmental:
Maximum Operating Altitude 2000 meters
Operating Temperature -40ºC to +60ºC
Storage Temperature -40ºC to +80ºC
Humidity 100% n.c.
Tropicalization Conformally coated PCBs;
Marine-rated terminals