Energy Saving Factory Pre-Program
The (-)HC-TST412MDMS thermostats are programmed with the energy saving settings shown in the table below for all days of
the week. If this program suits your needs, simply set the thermostat clock and press the RUN button.
The table below shows the factory set heating and cooling schedule for all days of the week.
* Wake Up Leave For Work * Return Home Go To Bed
(Morning) (Day) (Evening) (Night)
Heating
Program
Cooling
Program
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
6:00 AM 78°F 8:00 AM 85°F 5:00 PM 78°F 10:00 PM 82°F
* You can eliminate these two program periods in the confi guration menu (reference #3) if the building is occupied all day.
Day will change to 6:00 am and can be programmed as required.
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The (-)HC-TST412MDMS comes confi gured for 7 day programming and can also be confi gured for 5+1+1 programming (see
confi guration section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your
own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day fi ll in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
In Heating, lower temperatures will save energy.
In Cooling, higher temperatures will save energy.
If you plan on using Auto Changeover, do not program the heating higher than the cooling.
PROGRAMMING
Worksheet for Re-Programming 5+1+1 and 7 Day Program
Heating
Program
Wake Up
(Morning)
Fan
Leave For Work
(Day)
Fan
Return Home
(Evening)
Fan
Go To Bed
(Night)
Fan
MON
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
SUN
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
vvv
Cooling
Program
Wake Up
(Morning)
Fan
Leave For Work
(Day)
Fan
Return Home
(Evening)
Fan
Go To Bed
(Night)
Fan
MON
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
SUN
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto