SPECIFICATIONS:
FOG OUTPUT DIAGRAM
TYPICAL
SPARE PARTS
FOG TIME DIP 2-3-4
CONSUMER GOODS
90020209 XTRA
+
Fog fluid Bag 0,4 l
90020430 30 degree nozzle
SPP1060 Batteri 12V - 1,2Ah
SPP1075-0000 Thermo Sensor
SPP100-0025 Heating Rod
SPP100-0000 Print
White - Item no.: 90010101
Performance (fog generation): 60 sec.: 400 m
3
Fog generation settings: Can be timed at 3 intervals from 140 – 400 m
3
Total capacity (full  uid bag): 1800 m
3
Fluid bag: 0,4 litres
Electronic  uid measurement: Yes
Number of 60-sec. shots in one bag: 4
Pulse mode: Yes, can shoot several times (2 sittings)
Mains connection: 230 V, 50 Hz
Power consumption: 1050 W
Standby consumption after heating up: 60 W (on average)
Standby consumption when heat is disabled: 5-10 W
Heating time from cold: 8-10 min.
Re-heating time after fog discharge: 0-5 min.
Operating temperature (min./max.): 5/80° C.
Input: 5 signals
Output: 3 signals
Control settings for fog time, signals and heating:
On/off DIP switches
Battery backup: Yes. Please notice: QUMULUS
TM
is delivered without batteries
Power backup after mains connection loss: Up to 1 hour (requires batteries,
which are not delivered as standard).
Signals, indicators: Yes, optical, audible and electrical
Status indicator on PCB: Yes
External status indicator: Yes
Data log memory: Yes, export of data possible with IntelliSuite
TM
Dimensions (mm): L: 650 x B: 140 x H: 148
Installation weight: 10 kg
Possibility of 2 different angled nozzles: Yes, straight ahead and 30°
Compatible with PROTECT’s nozzle extension: No
Metal casing colour: White
QUMULUS
®
Dip Setting Fog Time Fog Volume
Dip 2 Dip 3 Dip 4 m
3
OFF OFF OFF demo -
ON OFF OFF 20s 140
OFF ON OFF 40s 230
ON ON OFF 60s 400
OFF OFF ON 60s + 2 min. 600
ON OFF ON 60s + 4 min. 900
OFF ON ON - -
ON ON ON - -
DISPLAY EXPLANATION
DISPLAY
H
Heating. The system is in the heating
phase and has not reached operating
temperature.
r
The system has reached normal operating
temperature and is ready to produce fog.
d
”Disable” input activated and system
blocked, as the alarm is not connected
(heating has not been disconnected).
Hd
”Heat Disable”. ”Disable” input activated
and system blocked, as the alarm is not
connected. Heating is also disconnected, as
dipswitch 1 is in the ON position.
bt
“Blocking timer active”. System blocked
from fog triggering internally (timer-con-
trolled). This occurs after the fog has been
triggered or in connection with system
start-up after loss of mains voltage.
A
“ARM” input activated.
P
“Primary Trig” input activated.
S
“Secondary Trig” input activated.
bAt
A battery is (or has been) mounted.
C
The battery is currently being charged.
E1
Mains voltage failure.
E2
Low  uid level.
E3
Fire alarm input activated.
E4
Low battery voltage.
E5
Failed attempts to charge the battery for
24 hours.
E6
Battery failed load test.
E7
PCB temperature too high.
E8
PCB temperature too low.
E9
Thermo-sensor temperature too high (or
connection lost).
E10
Thermo-sensor temperature too low
(after preliminary heating).
E12
Pump timeout. The pump has been running
for too long. Lack of  uid, etc.
E13
External 12 supply shut down due to
overload.
E14
Error in “load test circuit”.
DIP
Function
1
Heat disable. On = The heating element
disconnects if disable is activated
2 Fog time
3 Fog time
4 Fog time
5 Arm*
6 Primary*
7 Secondary*
8 Fire-alarm delay**
9 Reserved. Leave in OFF position
10
Error indicator. On = Beeper connected
* ON = normal open.
OFF = normal closed.
** ON = delay is active.
DIPSWITCH SETTINGS
Break Break
PROTECT Pulse Effect
TM
60 sec. fog Fog output Fog output Fog output Fog outputFog output
BreakBreakBreak
Display/
fault codes
DISPLAY / FAULT CODES
PrO Ec 600 EU
H. H: Heat
r. r: ready
d. d: disable
H.d. Hd: Heat disable
B. . Bt: Blocking timer
A. A: Arm trig
P. P: Primary trig
S. S: Secondary trig
b.A. . bat: battery
C. C: Charge
E. E: Error + no
1.234567890
1.234568790
rc. rc: Remotely controlled*
norc. norc: No remote control signal*
rd. Remotely disabled*
rHd. rHd: Remotely heat disabled*
rP. rP: Remote primary*
rb. rb: Remotely blocked*
rF. rF: Remote  re alarm*
rPA rPA: Remote panic alarm activated*