EasyManua.ls Logo

Protector PRO-LUX 7000 - Status and Error Messages (AS-7030;AS-7040); Heater Status and Errors; AS-7040 Window Status and Errors

Protector PRO-LUX 7000
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
38
Status
Heater off
Heater on
All
Battery
warning
Battery
empty
AS-7040
Window
open
Window
closed
Heater-Transmitter
1x flash slowly GN
After correct feedback
2x rapidly flashes
(3 min. test interval)
1x flash slowly RD
After correct feedback
2x rapidly flashes
(3 min. test interval)
–
–
–
–
–
Window-Transmitter
–
–
3x flash rapidly.
New communication
attempt.
Central not reached,
after 3 attempts
stopping communication
–
–
1x flash slowly GN
After correct feedback
2x rapidly flashes
1x flash slowly RD
After correct feedback
2x rapidly flashes
Jalousie-Transmitter
x
Non-existent
x
Non-existent
x
Non-existent
x
Non-existent
x
Non-existent
–
–
Central (acoustics)
–
1x beep
if window closed
–
–
–
–
1x beep
if heater on
Central (LED)
LED heater
permanent GN
LED heater
permanent RD
–
If heater/window on/
open permanent GN
with flashing RD.
If heater/window off/
closed flashing RD.
Power LED flashing RD.
Flashing Status LED
heater/window RD
LED window
permanent GN
LED window
permanent RD
Central (relay)
Power circuit
closed
Power circuit open,
if window closed
–
Relay according to
the state
(please refer window
open/closed)
Power circuit
open
Power circuit
closed
Power circuit open,
if heater on and
blinds closed