ALIGNMENT
IDLE
CURRENT
ALIGNMENT
dg
23
33
4.
Turn
VR603,
VR604
to
fully
counter
clockwise
position.
Remove
the
load
from
speaker
terminals.
Push
on
POWER
for
5
minutes
pre-heating.
Connect
DC
millivolt-meter
across
R651
for
left
channel
R652
for
right
channel.
The
meter
sensitivity
should
be
set
at
100mvV
full
scale
deflection.
.
Adjust
VR603
(left
channel)
and
VR6O04
(right
channel)
till
the
reading
from
meter
is
between
2.5mV
and
5.0mV
the
alignment
is
completed.
OFFSET
ALIGNMENT
dw
Dix
Six
Remove
the
load
from
speaker
terminals.
Push
on
POWER
for
5
minntes
pre-heating.
Connect
a
DC
millvolt-meter
to
speaker
terminals
of
each
channel.
The
meter
sensitivity
should
be
set
at
100mV
full
scale
deflection.
The
positive
input
of
the
meter
should
be
connected
to
the
red
(+)
speaker
terminal.
4.
Adjust
VR601
(left
channel)
and
VRO6O2
(right
channel)
till
the
meter
reading
is
zero.
The
alignments
is
completed.