The use of other chemicals is not usually required and they could cloud the pool water.
TROUBLESHOOTING GUIDE
PROBLEM PROBABLE CAUSE REMEDY
No light from
Prozone unit
Loose wiring
No power to unit
Defective lamp or other
internal component
Check all wiring
connections
Voltage compatibility
Check power source
Return unit to dealer
No bubbles from
injector
or no evidence of
ozone in pool
Excessive back
pressure
Leak in fitting
Filter not working
Check for kinks or clogs in
hose or plumbing
Replace fitting
Check filter
Water in Ozone
Generator
Check valve failure Verify check valve in
venturi is operating
properly
Cloudy water;
foamy water; scum
Water chemistry out of
balance
Total Dissolved Solids
(TDS) level too high
Filter not working
Check readings and
balance accordingly
Refer to dealer for proper
water testing
Clean or replace filter
NOTE: Cloudy water may occur when the ozone generator is started. Filter and backwash as necessary.
INSTALLATION KIT INVENTORY
PZ2-1 & PZ2-2 SERIES WITH BYPASS VENTURI
Tee, Saddle, 1-1/2 inch
x 3/4 inch
2 each Fitting, ½ inch MPT x 1/4
inch HB
2 each
Fitting, 3/4 inch MPT x
3/4 inch HB
2 each Injector, 3/4 inch HB 1 each
Valve, Check, ½ inch 1 each Hose, Polybraid, 1/4 inch 6 feet
(1.82m)
Hose, Clear Vinyl, 3/4
inch
8 feet
(2.4m)
Clamp, Plastic, Black,
0.500 inch
4 each
Clamp, Hose, Metal,
1.25 inch
4 each