Questions and Answers

  • D
    Donald PattersonAug 19, 2025
    What to do if the weight shown by PTM ADVANCE SUPER USB Accessories scale is not correct?
    • S
      Sara HooverAug 19, 2025
      If the weight shown by your PTM Accessories scale is incorrect, it might be due to a calibration issue. Carry out a new calibration of the system as indicated in the specific documentation. If the calibration was not successful, contact service.
  • A
    April RamseyAug 26, 2025
    How to fix a PTM Accessories scale that switches off when the alarm rings?
    • C
      cathy48Aug 27, 2025
      If your PTM Accessories weighing scale switches off when the alarm rings, the alarm may not be working properly and must be replaced. Disconnect the 2-pin connector of the alarm from the cable controlling it. The cable controlling the alarm could also be damaged, so replace it. If this doesn't resolve the issue, contact service.
  • E
    Elizabeth LawrenceSep 3, 2025
    What to do if my PTM ADVANCE SUPER USB Accessories scale does not switch on or shows 'Low Bat'?
    • J
      joshuasandersSep 3, 2025
      If your PTM Accessories scale doesn't switch on or displays 'Low Bat', verify that the power supply matches the product's technical specifications. Inspect the power supply cable for any damage or interruptions, and check the power plug and battery clamps for oxidation, replacing them if necessary. If these steps don't resolve the issue, contact service.
  • J
    John ChavezNov 11, 2025
    Why is the weight unstable on my PTM ADVANCE SUPER USB Accessories scale?
    • T
      Tyler JonesNov 11, 2025
      An unstable weight reading on your PTM Accessories scale, where the weight value goes up and down steadily, can be due to several factors. The scale might be out of range; in this case, pressing the T/CLEAR key may solve the problem through the scale software. Another reason could be that the tank lays on the frame, so arrange for the tank not to touch the frame in any point. Damaged cables can also cause fluctuations, so replace any damaged cables. It's also possible that one or more load cells aren't working correctly, or the connected load cell doesn't work properly. In such cases, disconnecting and reconnecting the load cells, one by one, can help identify the faulty cell. If the 5-pin female connector of the scale has humid contacts, use warm air to dry off the connector. If the weigh...