This electric scrubber is a high quality, precision made product. All
parts used in the manufacturing of this machine have passed rigid
quality control standards prior to assembly and an “each unit” final
inspection prior to packaging is your assurance of proper assembly.
This automatic scrubber was protectively packed to prevent possible
damage in transit. Should damage occur, please notify the trans-
porting carrier immediately for loss and/or claim.
Model ES2000
Automatic Scrubber
Operation & Care Instructions
MOTOR:
This electric scrubber is powered by a 3/4 HP brush motor and a 1
HP by-pass vacuum motor and will operate on 115V/60HZ only. Be
sure your power supply agrees with a voltage marked on the name-
plate. Voltage decreases of more than 10% will cause the motor to
slow down, thus increasing the current draw and opening the circuit
breaker.
IMPORTANT SAFEGUARDS
EXTENSION CORDS:
Machines that have 3-wire cords requiring grounding must only be
used with extension cords that have 3-prong grounding type plugs
and 3-pole receptacles.
To determine the minimum wire size required, refer to the chart
below:
Minimum Wire Size (AWG) of Extension Cord
Nameplate Total Extension Cord Length (Feet)
Rating-Amps 25 50 75 100 125 150 175 200
0-10.0 18 18 16 16 14 14 12 12
10.1-13.0 16 16 14 14 14 12 12 12
13.1-15.0 12 12 12 12 12 12 12
Before using an extension cord,inspect it for loose or exposed wires,
damaged insulation and defective fitting.
WARNING
RISK OF FIRE: Do not use with a flammable or combustible
liquid to clean a floor.
CAUTION
Always disconnect power cable from electrical outlet when
working on this machine.
This electric scrubber must be grounded. If it should malfunction or
breakdown, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock. This appliance is equipped
with a cord having equipment grounding conductor and grounding
plug. The plug must be inserted into an appropriate outlet that is prop-
erly installed and grounded in accordance with all local codes and ordi-
nances.
WARNING
Improper connection of the equipment grounding conductor can
result in a risk of electric shock. Check with a qualified electrician
or service person if you are in doubt as to whether the outlet is
properly grounded.
Do not modify the plug provided with the appliance if it will not
fit the outlet,have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120- Volt circuit,and has a
grounded plug that looks like the plug illustrated in sketch A below.
A temporary adapter that looks like the adapter illustrated in sketch-
es B and C may be used to connect this plug to a 2-pole receptacle
as shown in sketch B if a properly grounded receptacle is not avail-
able. The temporary adapter should be used only until a properly
grounded outlet (sketch A) can be installed by a qualified electrician.
The green colored ear,lug, or the like extending from the adapter
must be connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter is used,it must be
held in place by a metal screw.
NOTE: In Canada,the use of a temporary adapter is not permitted by
the Canadian Electrical Code.
GROUNDING INSTRUCTIONS

Other manuals for Pullman Holt ES2000

Question and Answer IconNeed help?

Do you have a question about the Pullman Holt ES2000 and is the answer not in the manual?

Pullman Holt ES2000 Specifications

General IconGeneral
ModelES2000
TypeFloor Machine
Motor Power1.5 HP
Voltage115V
Brush/Pad Diameter/Size20 inches
Cord Length50 feet

Summary

Important Safeguards

Motor Power Requirements

Details power requirements for the electric scrubber's motor and potential issues with low voltage.

Fire Risk Warning

Warns against using flammable or combustible liquids for cleaning floors with this scrubber.

Extension Cord Guidelines

Specifies requirements for 3-wire grounding cords and provides a chart for minimum wire size based on length.

Maintenance Caution

Advises disconnecting the power cable from the electrical outlet when performing maintenance.

Grounding Instructions

Grounding Safety Warning

Highlights the risk of electric shock from improper grounding and advises consulting an electrician.

About the Machine

Assembly and Brush Attachment

Covers complete assembly, attaching the brush, and preparing for operation.

Operation and Stopping Procedures

Details how to operate the scrubber, including brush and squeegee control, and stopping procedures.

Care and Maintenance

Provides guidance on maintaining solution/recovery tanks and replacing squeegee blades.

Troubleshooting Guide

Motor and Noise Issues

Addresses common problems like the motor not running or the scrubber running slow or noisy.

Solution and Vacuum Flow Problems

Guides on diagnosing and fixing issues with solution flow and vacuum performance.