Operaon & Installaon Instrucons
PULSAR - Standard Systems
System
Rated Flow
System
Rated Flow
405-PUV-100-02
405-PUV-200-02
405-PUV-300-02
2 gpm
405-PUV-HO-100-04
405-PUV-HO-200-04
405-PUV-HO-300-04
4 gpm
405-PUV-100-03
405-PUV-200-03
405-PUV-300-03
3 gpm
405-PUV-HO-100-10
405-PUV-HO-200-10
405-PUV-HO-300-10
10 gpm
405-PUV-100-06
405-PUV-200-06
405-PUV-300-06
6 gpm
405-PUV-HO-100-14
405-PUV-HO-200-14
405-PUV-HO-300-14
14 gpm
405-PUV-100-10
405-PUV-200-10
405-PUV-300-10
11 gpm
405-PUV-HO-100-25
405-PUV-HO-200-25
405-PUV-HO-300-25
25 gpm
405-PUV-100-15
405-PUV-200-15
405-PUV-300-15
15 gpm
405-PUV-HO-100-40
405-PUV-HO-200-40
405-PUV-HO-300-40
40 gpm
405-PUV-100-20
405-PUV-200-20
405-PUV-300-20
21 gpm
PUV-200
Series
PUV-HO-200
Series
PUV-300
Series
PUV-HO-300
Series

Questions and Answers

  • C
    Christian WillisAug 7, 2025
    How to fix low UV intensity in Pulsar Ultraviolet Water Filtration Systems?
    • B
      Brittany YoungAug 7, 2025
      If the Pulsar Ultraviolet Water Filtration System displays a low UV intensity, you should first remove and clean the quartz sleeve and sensor. Also, verify that your water quality meets the requirements specified on page 5 and consider adding filtration if needed. If the issue persists, replace the lamp.
  • J
    jeffersontheresaAug 12, 2025
    What to do if Pulsar Ultraviolet 405-PUV-200-20 Water Filtration Systems detect a problem with the lamp?
    • S
      Steven BryantAug 12, 2025
      If the Pulsar Ultraviolet Water Filtration System detects a problem with the lamp, try resetting the lamp protection circuit by unplugging the unit for 10 seconds. If the problem continues, replace the lamp with the correct part number as indicated on the silver label located on the reactor or on the Maintenance parts screen.
  • S
    Stephen MartinAug 17, 2025
    What to do if UV sensor is no longer communicating with Pulsar Ultraviolet 405-PUV-200-20 Water Filtration Systems?
    • S
      smithmichelleAug 17, 2025
      If the UV sensor is no longer communicating with the Pulsar Ultraviolet Water Filtration System, first ensure that all modules are properly connected to the system and to each other. Modules can be tested individually by plugging them in one at a time and cycling power to the system. Replace any module that is not detected when plugged directly into the controller.
  • T
    tammyhuntAug 21, 2025
    Why is my Pulsar Ultraviolet 405-PUV-200-20 lamp on but not disinfecting?
    • E
      Emily AlvaradoAug 22, 2025
      If the lamp in your Pulsar Ultraviolet Water Filtration System is powered and visibly illuminated but not disinfecting properly, it may be due to the lamp's age. Replace the lamp with the correct part number as indicated on the silver label on the reactor or on the Maintenance parts screen.
  • M
    michael79Aug 27, 2025
    What to do if Pulsar Ultraviolet 405-PUV-200-20 Water Filtration Systems says lamp key is missing or incorrect?
    • T
      Thomas BenjaminAug 27, 2025
      If the Pulsar Ultraviolet Water Filtration System indicates a missing or incorrect lamp key, ensure the lamp key (packed with the lamp, on the connector) is installed. If it is already installed, try unplugging and reinstalling the key. Also, verify that the key part number matches the lamp listed on the Maintenance Parts screen.
  • T
    tfoleySep 1, 2025
    What happens if wrong lamp or sensor installed in Pulsar Ultraviolet Water Filtration Systems?
    • R
      ronald80Sep 1, 2025
      If the wrong lamp or sensor is installed in the Pulsar Ultraviolet Water Filtration System, replace the component with the proper model as indicated.

Summary

Pulsar Ultraviolet Operation & Installation

Safety and Preparation Guidelines

General Safety Precautions

Lists essential safety rules for operating and maintaining Pulsar UV systems.

Water Quality Requirements

System Assembly - Standard Output

System Assembly - High Output

System Sizing and Installation Location

Installation Procedure - Part 1

Reactor Mounting and Bypass Setup

Details mounting the reactor, recommended bypass assembly, and flow restrictor installation.

Plumbing Connections and Regulations

Covers connecting the reactor to water supply and adhering to local regulations.

Installation Procedure - Part 2

Quartz Sleeve and UV Sensor Installation

Guides on installing the quartz sleeve, gland nut, spring, and UV sensor.

Water Flow Check and Controller Mounting

Instructions for checking leaks, water flow, and mounting the system controller.

Installation Procedure - Part 3

Lamp and Electrical Connections

Covers lamp insertion, key connection, grounding, and final power connection to GFCI outlet.

System Disinfection and Quartz Sleeve Maintenance

UV Sensor Cleaning and Operation Basics

System Troubleshooting - Hard Alarms

Diagnosing and Resolving Hard Alarms

Covers troubleshooting common hard alarms related to lamp failure, sensor issues, and connections.

System Troubleshooting - Soft Alarms and Advisories

Diagnosing and Resolving Soft Alarms

Addresses troubleshooting soft alarms for module communication failures and connection issues.

Boil Water Advisory Guidance

Provides critical advice on water safety and boiling requirements during system failures.

Pulsar Standard Output System Specifications

Pulsar-HO High Output System Specifications

Pulsar UV System Warranty Statement

Warranty Coverage and Exclusions

Outlines the warranty periods for systems, electronics, and lamps, along with key limitations.

Warranty Service and Registration

Pulsar Ultraviolet 405-PUV-200-20 Specifications

General IconGeneral
Model405-PUV-200-20
Wavelength254 nm
Power Consumption200 W
UV Dose40 mJ/cm²
Operating Temperature2-40°C (35-104°F)
CertificationsNSF/ANSI