For quick disconnect pipe
connections, purchase separately
Part No. 42001-0402 Union Kit) .
Kit Includes:
2 #U11-200PS Union Collars
2 #U9-362 O-Ring
2 #U11-196PS 2" Slip Adapter
REPAIR PARTS LIST
Parts are common to all models except as noted:
Key Nos.1, Motor are listed below.
Key Part Part
No. Description Qty. Number
1 Motor 1 See Chart
2 Screw #10-32x1/2" 1 U30-692SS
3 Bonding Lug 1 U17-568
5 Seal Plate 1 C3-184P
6 Seal Plate Cord Ring 1 U9-373
7 Shaft Seal 1 359607S
8 Impeller 1 See Chart
10 Diffuser 1 C1-270PC
11 Diffuser O Ring 1 U9-374
12 Pump Body (Only) 1 17303-0001
13 Drain Plug and O-Ring 1 U178-920P
14 Hi-Lo Screw 5/16-14x5/8" 2 U30-919SS
15A Base - Corrosion Resistant 1 C4-77P
16A Motor Pad - for Corrosion Resistant Base 1 C35-45
17 Screw #8-32x7/8" Rd. Hd. 7 U30-542SS
18 Lock Washer #8 Ext. Tooth 7 U43-21SS
19 Flat Washer 3/8" 6 U43-62SS
20 Lock Washer 3/8" 6 U43-12SS
21 Nut 3/8-16 Hex 6 071403
22 Cap Screws 3/8-16x1" Hex. 4 U30-74SS
Nameplate 1 32155-7117
Tag, “Warning/Caution/Instruction” 1 C63-12
Motor No. Impeller
Model No. HP (Key No. 1) (Key No. 8)
79214 1 6203-2029 C105-236PB
Note: (•) Not illustrated.
10
NOTE: This booster pump is designed without a
strainer. However, a strainer that meets NSF 50
requirements can be used with the pump.