Possible cause
Calibration is required.
Solution
Perform the calibration according toCalibration Modesection.
Black screen after calibration
Solution
If the image does not clear after calibration, you need to recalibrate.
Poor quality image. There is noise or ghost
images of previous scenes or objects
Possible cause
Manual calibration has been performed with the lens cover open.
Solution
Check the Calibration Mode, close the lens cover and calibrate the
device.
The image is too dark
Possible cause
Brightness or contrast level is too low.
Solution
Adjust the brightness or contrast level in the Quick Menu.
Colour bars appear on the display or the
image disappears

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pulsar Axion 2 XG35 and is the answer not in the manual?

Pulsar Axion 2 XG35 Specifications

General IconGeneral
Thermal Sensitivity<40 mK
Frame Rate50 Hz
Objective LensF35/1.0
Sensor TypeUncooled Microbolometer
Display TypeAMOLED
Built-in Memory16 GB
Wi-Fi Channel2.4 GHz
Protection DegreeIPX7
Operating Temperature Range-25°C to +50°C
Power Supply3.0 - 4.2 V
Battery Capacity4900 mAh
Magnification2x - 8x
Detection Range1750 meters
Display Resolution1024x768 pixels
Video / Photo Resolution1024x768
Video / Photo FormatMP4 / JPG
Battery TypeLi-Ion
Sensor Resolution384x288 pixels

Related product manuals