Single Measurement Mode
1.
Turn on the device, set up image according to section Powering on
and Image Setting.
2.
When briefly pressing the LRF (6)button– the rangefinder mark will
appear on the screen, empty blanks of range values with the unit of
range measurement will appear in the upper right corner of the image,
i.e. the rangefinder module switches into measurement standby mode.
3.
If PiP mode is activated, the aiming reticle disappears upon activation
of the rangefinder and the PiP window remains active.
4.
Point the rangefinding reticle at an object and press the LRF (6)button.
5.
In the top right corner of the display you will see distance in meters (or
yards - depending on settings).
Note: if the rangefinder is idle longer than for 4 seconds, it turns off
automatically.
Scan Mode
1.
To measure distance in scanning mode, hold down the LRF (6) button
for longer than two seconds. Measurement readings will be changing in
real time as you point the binoculars at different objects. A SCAN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pulsar Merger LRF XP50 and is the answer not in the manual?

Pulsar Merger LRF XP50 Specifications

General IconGeneral
Objective Lens Diameter50 mm
Detection Range1800 m
Laser RangefinderYes
Wavelength905 nm
Built-in Memory16 GB
Wi-FiYes
Stream Vision 2Yes
Waterproof LevelIPX7
Display Resolution1024x768
Video / Photo FormatMP4, JPG
External Power SupplyUSB-C
Operating Temperature Range-25 … +50 °C

Related product manuals