Installation (cont.)
Impact 6 Case Engineering Data & Set Points
Pure Cold Impact 6 Installation,
Operation & Maintenance Manual
Model
doors
Refrig
Volume, Cu.Ft
Exterior Dimensions, Inches
1PS4MA1 4ft
2
R290
41.33
48*30*79.5
1PS4MA1 6ft
3
R290
61.7
72*30*79.5
1PS4MA1 8ft
4
R290
82.66
96*30*79.5
Model
Hz/Ph
Volts
Run Amps
NEMA
Plugs
A/C load, W
Energy
Consumption,
Kwh/day
Appox ship
Wt(kg)
1PS4MA1 4ft
60/1
115
3.4
LK7515P
395
4
230
1PS4MA1 6ft
60/1
115
5.7
LK7515P
655
6.6
320
1PS4MA1 8ft
60/1
115
8.5
LK7515P
930
7.6
400
Model
settings
set rd di dp dt dd c0 c1 c2 a4
h4
1PS4MA1 4ft 33 7 6 45 44.6 3 3 0 3 1 0
1PS4MA1 6ft 33 7 6 45 44.6 3 3 0 3 1 0
1PS4MA1 8ft 33 7 6 45 44.6 3 3 0 3 1 0
Specifications
Electrical
Controller setting