Product Type Meat / Dairy
Maximum Design Ambient 75
o
F 55%RH
Case Length 4ft (1220mm) 6ft (1830mm) 8ft (2440mm)
Physical Data
TDA (Total Display Area) ft
2
20.3 30.48 40.64
Refrigerated Volume (V
r
) ft
3
30.45 45.72 60.96
Shelf Depth nominal (in) 20” (door)
18”(open)
20” (door)
18”(open)
20” (door)
18”(open)
Electrical Data (115v 60Hz) Amps Amps Amps
Case Load 0.5 1.0 1.0
Electrical Data (208v 60Hz)
Condensing Unit 4.5 6.0 8.5
MOCP (per phase) Amps 10 10 15
Energy Data - Standard
Total Heat Rejection THR (BTU/hr) instantaneous 8,345 12,092 16,872
Total Heat Rejection THR (BTU/hr) average 7,564 11,065 15,340
Nett Environmental Cooling Effect (BTU/hr) 2,642 4,572 6,175
Daily Energy Use (kWh) 17.55 21.68 34.1
Energy Data - NGR
Total Heat Rejection THR (BTU/hr) instantaneous 6,564 9,468 12,624
Total Heat Rejection THR (BTU/hr) average 5,420 6,680 10,431
Nett Environmental Cooling Effect (BTU/hr) 2,183 2,687 4,199
Daily Energy Use (kWh) 12.07 14.86 23.22
Energy Data - Doors
Total Heat Rejection THR (BTU/hr) instantaneous 6,564 9,468 12,624
Total Heat Rejection THR (BTU/hr) average 3,282 4,734 6,312
Nett Environmental Heating Effect (BTU/hr) 2,953 4,260 5,680
Daily Energy Use (kWh) 5.24 7.72 10.30
Miscellaneous Data
Electrical Connections Bottom Right Hand Side
Number Refrigeration Systems 1 1 1
Refrigerant Charge (R448A) per system (lbs) 4 4.5 6.5
1
Installation, Operation & Maintenance
Manual
Pure Cold Inc
1PS4M A1
Self-Contained Medium Temperature Display Case
Issue Date: September 2023
Rev1
© Pure Cold Incorporated
Compliant with DOE2017 Thresholds
Pure Cold Impact 6 Installation,
Operation & Maintenance Manual
WARNINGS: This product contains R290 Hydrocarbon flammable
refrigerant so care must be taken to follow these instructions to
avoid the risk of damage to property or personnel injury