EasyManua.ls Logo

purecold 1PS4MA1 - Case Cleaning Procedures

purecold 1PS4MA1
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
User Information (Cont.)
Case Cleaning
Always electrically isolate case before carrying out any work.
Weekly Clean
- Wipe down the internal panels and all areas that may contact retail products. Use a
damp cloth with a mild soap solution.
- Wipe down the front panel with a damp cloth (which may otherwise attract dust where
the air is sucked in.)
- Dependent on type of product being displayed, some cases will require more frequent or
daily cleaning.
Six Weekly Clean
- Carry out the weekly clean
- Remove and wash removable condensing unit mesh
- Clean the front of the Condenser Unit using an evaporator comb to remove dust
and other particles. Take care not to damage refrigeration pipes
Six Monthly Deep Clean
- Deep cleans should be carried out involving dismantling, cleaning and inspecting the case to
ensure correct operation of all areas. Only qualified personnel should carry out this process.
-When cleaning cases only use non-abrasive, odourless detergent cleaner suitable for food
hygiene environments, diluted to the manufacturers recommended concentration.
- When cleaning debris from the case base, in order to avoid blockages or damage, the
following points must be observed:
- When working inside the case take care not to damage any components such as fan
blades or probes and do not put strain on any cables.
- Where electrical components are fitted with plug and sockets, these should be
removed prior to cleaning.
- Do not directly apply water to fan motors or any other electrical components in the
case.
- Only use a soft cloth and mild glass cleaner for cleaning glass or mirrored
components. - Be sure to rinse and/or dry completely.
- Only the internal drain of the case may be rinsed out with clean water providing the
case is connected directly to the mains drainage.
- If the case is connected to only to the evaporative tray, care must be taken not to
overfill the tray.
- It is recommended that the case drainage ā€˜U’ bend is disconnected, cleaned out, and
reconnected
Pure Cold Impact 6 Installation,
Operation & Maintenance Manual