28
DOs & DON’Ts
Pureit Advanced has been specially designed to give you water that is ‘Safer Than Boiled Water’ as long as
the Pureit Advanced system is used in the way as prescribed in this manual.
Listed below are the things that you must take care of:
DO’s
DON’Ts
Clean the Top Lid, the Top Chamber, the Cleansing Collection Chamber and
the tap regularly
Clean with water and then leave the components to ‘drip dry’
Clean the tap with a mild hypochlorite solution
If necessary, use a plastic brush to aid cleaning
Remove the Germkill Processor™ while cleaning and keep upright in a
separate dry place
Empty the water from the Cleansing Collection Chamber before removing the
Microcharged Membrane assembly
Remove the Germkill Processor™ before emptying out the water from the
Cleansing Collection Chamber
The Pureit guarantee of getting water that is ‘Safer Than Boiled Water’
applies only if you ensure that the Transparent Chamber of the purier and
the tap are hygienically kept, and that germs are not introduced due to
contact with hands, drying with a cloth, wash or any other means
You should only store water in Pureit Advanced purier and not use other
bottles and containers, to avoid re-contamination of the water
Always use all three components of the Pureit Advanced Germkill Kit™
together
You should ensure that the area around and beneath the purier is kept
clean at all times
Keep all components of the Pureit Advanced Germkill Kit™ out of reach of
children at all times
Do not clean with soap or detergent, or any abrasive cleaners or tools like wire Mesh
Do not twist the Advanced Microbre Mesh™ while cleaning. The Advanced
Microber Mesh™ might change its color over a period of time. This does not
affect the performance of the Advanced Microber Mesh™
Do not use any soap or detergent. Ensure that you don’t inadvertently introduce
germs into the Transparent Chamber or the tap e.g. through your hands or by
using a drying cloth. Always use puried Pureit Advanced water for doing the last
rinse of the Transparent Chamber, and then let it drip-dry
Do not normally wash the Cleansing-Collection Chamber
Don’t pour boiling or hot water (more than 50˚C) into, or on the Pureit Advanced
system. Similarly don’t pour freezing cold water (less than 10˚C) into, or on the
Pureit Advanced system
Do not pour hot water directly from an overhead tank or any other source in your
Pureit Advanced as hot water uses up the Germkill Kit™ faster than normal. If
required, allow the water to cool to room temperature before pouring it in the Top
Chamber. For the same reason do not keep your Pureit Advanced in hot surroundings
like direct sunlight, near a stove or near a fridge
Never buy the Pureit Advanced system, or a Pureit Advanced Germkill Kit™ from an
unauthorized source. You can visit a store near you to buy a Germkill Kit™ or call us
at the Pureit helpline, and we will deliver a new Germkill Kit™ to you at your home
for a minimal delivery charge
Don’t in any way try to open the three Pureit Advanced Germkill Kit™
components
Never use the system once the Pureit Advanced Germkill Life Indicator™ shows a
full red colour in the window, with no white colour visible
Don’t expose any of the components to re