Installation Instructions
1. Ideally, the booster pump should be installed between your sediment filter and carbon
stage, however, if this is not possible, it can also be installed before the RO system in the feed
water line. Installing it between the sediment filter and carbon stage offers some extra
protection to your booster pump by ensuring only filtered water passes through it, preventing
it from becoming clogged up in future.
2. The PurePro HF-8367 RO Booster Pump has both an inlet and outlet connector. This is
indicated by arrows which illustrate the direction of flow.
3. Connect your system’s white feed water inlet tube to the 1/4” Jaco style input on the booster
pump by inserting the tube as far into the fitting as possible and tightening the nylon nut until
no more thread can be seen. If necessary a shifter will make tightening the nut easier.
4. Next connect one end of a tube to the output on the booster pump and tighten as per the
previous step. Connect the other end of the tube to your RO/Di systems input connector.
5. To complete the installation, connect the pump to the supplied AC adaptor.
When Turning the System Back On…
Once the pump is running on your system, you will notice a significant increase in water pressure on
your system’s pressure gauge, typically between 80 psi and 95 psi. Your system will be producing an
increased amount of product water and also a lower TDS than before the installation.