EasyManua.ls Logo

Puretec HYBRID H6 - User Manual

Puretec HYBRID H6
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For correct operation & installation it is essential to observe these instructions.
Filtration & Ultraviolet Disinfection All in One Unit
Hybrid User Guide
ATS5200.103
Licence No. WM 74593
ApprovalMark
SEPT2016

Questions and Answers

  • L
    Lance RobertsAug 16, 2025
    What to do if the red lamp blinks and buzzer sounds on Puretec Water Filtration Systems?
    • J
      James HillAug 16, 2025
      If the red lamp is blinking and the buzzer is sounding on your Puretec Water Filtration System, it means that the lamp has either reached or is nearing the end of its life. Replace the lamp before the lamp counter reaches 0. Alternatively, the lamp might be disconnected or faulty, so check the lamp connection and replace the lamp if necessary.
  • J
    jennifer89Aug 19, 2025
    What to do if a leak is detected at the filters of a Puretec Water Filtration System?
    • S
      Sandra CrosbyAug 19, 2025
      If you've detected a leak at the filters of your Puretec Water Filtration System, it could be caused by a damaged, deteriorated, or incorrectly installed O-ring. To fix this, remove the sump, wipe the O-ring and threads clean, ensure the O-ring is fitted properly, then reinstall. Alternatively, the filter cartridge might not be centered. Remove the sump, check for any damage to the cartridge, and reassemble, making sure the cartridge is centered.
  • C
    Catherine HallAug 22, 2025
    What does Error Code ‘A3’ on the ballast mean for Puretec HYBRID H6?
    • J
      justinwilliamsonAug 22, 2025
      If you see Error Code ‘A3’ on the ballast of your Puretec Water Filtration System, it means the ballast countdown has reached 0, and the lamp life has expired. You need to replace the lamp.
  • R
    Renee DelgadoAug 26, 2025
    How to troubleshoot a Puretec Water Filtration System with no power?
    • K
      kimtoddAug 26, 2025
      If your Puretec Water Filtration System has no power, it could be due to a tripped ballast or breaker. Try resetting them. If that doesn't work, the ballast might be damaged and require replacement.
  • J
    Jordan MaysAug 28, 2025
    Why does the ballast or breaker repeatedly trip on my Puretec Water Filtration System?
    • J
      John HardinAug 29, 2025
      If the ballast or breaker repeatedly trips in your Puretec Water Filtration System, the connection between the lamp and lamp plug may be wet. You should clean and dry the lamp pins and lamp plug, and check the unit for leaks or condensation. Alternatively, there could be a short-circuit in the electrical assembly, requiring you to replace the ballast.
  • W
    wacostaAug 31, 2025
    What to do if the lamp timer on my Puretec Water Filtration System does not read anything?
    • S
      Samantha PhillipsSep 1, 2025
      If the lamp timer on your Puretec Water Filtration System isn't displaying anything, start by ensuring the unit is plugged into a working AC power outlet. If it is, check the outlet itself—the fuse may need replacing, or the breaker may need resetting. A damaged power cord could also be the culprit, requiring replacement. Finally, a power surge might have damaged the electrical assembly, in which case the ballast needs to be replaced.
  • T
    Timothy CardenasSep 3, 2025
    Why does my Puretec Water Filtration System show bacterial contamination even when operating?
    • M
      myersjenniferSep 3, 2025
      If your Puretec Water Filtration System is running, but water tests still show bacterial contamination, ensure that the UV system is the final piece of treatment equipment. Also, pathogens might be present in the distribution lines after the UV system. Finally, if the lamp has reached its maximum life, replace it before the lamp counter reaches 0.
  • E
    Edwin OchoaSep 6, 2025
    How to fix a leak at the inlet or outlet of a Puretec Water Filtration System?
    • J
      johnsonwillieSep 6, 2025
      If you notice a leak at the inlet or outlet of your Puretec Water Filtration System, it could be due to leaking threaded pipe fittings. Clean the threads, reseal them with Teflon tape, and retighten. Another cause might be cracked heads, which would require replacement.
  • K
    Kathy ScottSep 9, 2025
    What causes leaks from the UV chamber area in Puretec Water Filtration Systems?
    • K
      Kristy McguireSep 10, 2025
      If you find a leak coming from the UV chamber area of your Puretec Water Filtration System, it could be due to a few reasons: * Condensation may be forming on the cold chamber. Try controlling the humidity or moving the unit. * The O-ring might be damaged, deteriorated, or not correctly installed. Inspect it and replace it if it looks worn. * The lamp/sleeve assembly might not be properly tightened. Tighten it by hand until it's snug.
  • L
    Lisa CunninghamSep 12, 2025
    Why is the display flashing on my Puretec Water Filtration System?
    • M
      Michael RuizSep 12, 2025
      If the display is flashing on your Puretec Water Filtration System, it indicates a power interruption. You should reset the ballast.