For correct operation & installation, it is essential to observe these instructions.
JUL2020
WMTS103:2016
Certicate No. WM 74593
Australian Certication
Services
User Guide
Filtration & Ultraviolet All-in-One Unit
Hybrid Series

Questions and Answers

  • A
    Angel JenkinsAug 16, 2025
    What to do if the red lamp blinks and buzzer sounds on my Puretec Water Filtration Systems?
    • F
      Frank NicholsonAug 16, 2025
      If the red lamp blinks and the buzzer sounds on your Puretec Water Filtration System, it means the lamp is nearing or has reached its maximum life. Replace the lamp as soon as possible, ensuring it's done before the lamp counter reaches 0. Also, check the lamp connection and replace the lamp if it is faulty or disconnected.
  • A
    Amy EspinozaAug 19, 2025
    What does error code ‘A3’ on my Puretec Water Filtration Systems ballast mean?
    • C
      cheryl74Aug 19, 2025
      If you see error code ‘A3’ on the ballast of your Puretec Water Filtration Systems, it indicates that the ballast countdown has reached 0, meaning the lamp life has expired. You need to replace the lamp.
  • J
    James WardAug 22, 2025
    Why is there a leak detected at the filters of my Puretec Water Filtration Systems?
    • T
      Tommy PhamAug 22, 2025
      If you detect a leak at the filters of your Puretec Water Filtration System, it could be due to a damaged, deteriorated, or incorrectly installed O-ring. Remove the sump, wipe the O-ring and threads clean, ensure the O-ring is fitted properly, and then reinstall. Another possible cause is dry O-rings, in which case you should lubricate them with a suitable sealant. Lastly, the filter cartridge might not be centered; remove the sump, check for cartridge damage, and re-assemble ensuring the cartridge is centered.
  • K
    Karen ColonAug 25, 2025
    Why is my Puretec Water Filtration Systems showing bacterial contamination even when it's operating?
    • M
      Megan HoweAug 26, 2025
      If your Puretec Water Filtration System is operating but water tests reveal bacterial contamination, it could be due to several reasons. First, ensure the UV system is the last piece of treatment equipment. Second, pathogens might be residing in the distribution lines post-UV, so remove any pipe dead-ends and flush with chlorine. Finally, the lamp may have reached its maximum life; replace the lamp when the lamp counter reaches 0.
  • K
    Kathryn JacksonAug 27, 2025
    Why does the lamp timer not read anything on my Puretec HYBRID?
    • B
      Brian BrownAug 28, 2025
      If your Puretec Water Filtration System's lamp timer isn't reading anything, first, ensure the unit is plugged into a working AC power outlet. If it is plugged in, check if there's power at the outlet by testing the fuse or resetting the breaker. A damaged power cord can also be the culprit, so replace it if necessary. Lastly, a power surge might have damaged the electrical assembly, in which case you should replace the ballast.
  • D
    Dr. Daniel Vasquez DDSAug 31, 2025
    How to fix a leak at the inlet or outlet of Puretec Water Filtration Systems?
    • N
      Natasha HarrisonAug 31, 2025
      If you find a leak at the inlet or outlet of your Puretec Water Filtration System, and the threaded pipe fittings are leaking, clean the threads, reseal them with Teflon tape, and retighten. If the heads are cracked, you will need to replace them.
  • S
    Shawn JamesSep 2, 2025
    How to troubleshoot no power in Puretec Water Filtration Systems?
    • M
      michelethompsonSep 3, 2025
      If your Puretec Water Filtration System has no power, the ballast or breaker might have tripped. Try resetting the ballast or breaker. If that doesn't work, the ballast may be damaged and needs to be replaced.
  • C
    Calvin SanchezSep 5, 2025
    What to do if I detect a leak from the UV chamber area of my Puretec Water Filtration Systems?
    • Z
      znunezSep 6, 2025
      If a leak is detected from the area of the UV chamber in your Puretec Water Filtration System, it could be due to condensation. Try to control the humidity or relocate the unit. It could also be that the O-ring is damaged, deteriorated, or incorrectly installed; inspect it and replace it if necessary. Another possible cause is that the lamp/sleeve assembly is not properly installed, so tighten the assembly hand-tight.
  • K
    kelli59Sep 9, 2025
    Why does the ballast or breaker repeatedly trip on my Puretec HYBRID Water Filtration Systems?
    • J
      Justin JacksonSep 9, 2025
      If the ballast or breaker repeatedly trips on your Puretec Water Filtration System, the connection between the lamp and lamp plug may be wet. Clean and dry the lamp pins and lamp plug, and check the unit for leaks or condensation. Alternatively, there may be a short-circuit in the electrical assembly, in which case you should replace the ballast.
  • T
    Timothy PowellSep 12, 2025
    Why is the display flashing on my Puretec Water Filtration Systems?
    • S
      Susan WongSep 12, 2025
      If the display is flashing on your Puretec Water Filtration System, it indicates a power interruption. Reset the ballast to resolve this issue.

Summary

System Preparation and Unboxing

Installation Guide and System Placement

Power Surge Protection

Information on protecting the system from electrical surges and recommended surge protector usage.

Installation Requirements and Guidelines

Application Warning for Water Quality

Critical water quality parameters must be met for proper Radfire™ operation and continuous protection.

Installation Procedure Steps

Initial Installation Procedure

Step-by-step guide for the initial setup and installation of the Puretec Hybrid Series.

System Operation

Replacement Parts Guide

Filter Cartridge Replacement Procedure

UV Lamp Replacement Procedure

Quartz Sleeve Maintenance and Replacement

Troubleshooting Guide

Troubleshooting Common System Issues

Lists common symptoms, their possible causes, and solutions for system malfunctions.

Puretec HYBRID Series Specifications

General IconGeneral
Filter Life6-12 Months
Maximum Pressure100 psi
Maximum Temperature40°C
Connection Size1 inch BSP
Warranty1 year
ApplicationWhole House
Filtration TechnologySediment and carbon
Operating TemperatureMin 4°C - Max 40°C
Connection Size Alternate1" BSP

Related product manuals