5.19 PROGRAM INPUT STATUS [400]
Each of the 6 inputs onboard the V2 GSM can be programmed to be either normally open,
normally high, normally low or a voltage trigger.
Press the [ or ] keys to scroll to
‘PROGRAM INPUT STATUS’ or
enter ‘400’.
Press B or T to choose the input
number or enter the function shortcut
number (see below). Press t
Press B or T to choose between
the input status, or select the number:
0 = Disabled
1 = Normally Open = Default
2 = Normally Low
3 = Normally High
4 = Voltage Trigger
Press t
Shortcut function numbers:
ONBOARD INPUTS
401: Program status for inp#1
402: Program status for inp#2
403: Program status for inp#3
404: Program status for inp#4
405: Program status for inp#5
406: Program status for inp#6
INPUTS ON THE INPUT EXPANDER
407: Program EXP. input#7
408: Program EXP. input#8
409: Program EXP. input#9
410: Program EXP. input#10
411: Program EXP. input#11
412: Program EXP. input#12
413: Program EXP. input#13