5.20 INPUT 1-6 RESPONSE TIME [450]
This is the response time it will take for an input to activate (can only be programmed for
the V2 GSM onboard inputs only, function not available for the RIX inputs).
Press the [ or ] keys to scroll to
‘INPUT 1-6 RESPONSE TIME’ or
enter ‘450’.
Press B or T to choose the input
number or enter the function shortcut
number (see below).
Press t
Press B or T to choose the
response time or select the number:
0 = 300ms = Default
1 = 5 seconds, 2 = 30 seconds
3 = 60 seconds, 4 = 3 hours
5 = 6 hours, 6 = 12 hours
7 = 24 hours, 8 = 1 week
9 = 2 weeks, Press t
Shortcut Function Numbers:
451: Response for input#1 454: Response for input#4
452: Response for input#2 455: Response for input#5
453: Response for input#3 456: Response for input#6
5.21 INPUT 1-6 TRIGGER VOLTAGE [500]
This function sets the trigger voltage for each individual input (the V2 GSM onboard inputs
only, function not available for the RIX inputs).
Press the [ or ] keys to scroll to
‘INPUT 1-6 TRIGGER VOLTAGE’ or
enter ‘500’.
Press B or T to choose the input
number or enter the function shortcut
number (see below).
Press t
Press B or T to choose the
trigger voltage. The choices range
from 0V and then increases in 0.5V to
15V. Press t
Shortcut Function Number:
501: Trigger volts for inp#1 504: Trigger volts for inp#4
502: Trigger volts for inp#2 505: Trigger volts for inp#5
503: Trigger volts for inp#3 506: Trigger volts for inp#6