Do you have a question about the Pytes V Series and is the answer not in the manual?
Essential instructions for qualified personnel regarding installation, operation, and maintenance procedures.
Precautions against short-circuiting, dismantling, improper use, and environmental hazards.
Information on severe risks like battery explosion, toxic exposure, and electric shock hazards.
Lists standard components for V5 and V5α models, with images.
Details Battery Management System functions for protection, alarm, management, and monitoring.
Diagram illustrating the front panel layout and components of the V5 and V5α battery units.
Detailed descriptions of each component on the battery, including their labels and functions.
Procedures and regulations for transporting Li-ion batteries, emphasizing protection against damage.
Recommendations for storing the battery, including temperature, humidity, and charge level maintenance.
Covers safety requirements and initial checks before installing the battery system.
Details necessary tools and technical preparations, including electrical settings and safety inspections.
Instructions for safely unpacking the battery and the process for installing it, either vertically or horizontally.
Steps for properly connecting the ground cable to the battery and ensuring correct grounding resistance.
Guidance on selecting and connecting power cables for single-rack and multi-rack configurations, including parallel connections.
Details on connecting cascade communication cables for single-rack and multi-rack systems, including master/slave configurations.
Information on using the WiFi port for data collection, cloud platform integration, and firmware upgrades.
Explanation of battery status indications through LED lights, including protection, alarm, and normal operation states.
Troubleshooting steps for when the battery fails to power on or respond to the start button.
Steps to resolve problems where the battery does not charge properly, including checking connections and protection states.
Solutions for issues preventing the battery from discharging correctly, focusing on connections and protection.
Troubleshooting when the ALM indicator is constantly red, suggesting a protection state that needs release.
| Nominal Voltage | 51.2V |
|---|---|
| Nominal Capacity | 100Ah |
| Energy | 5.12 kWh |
| Usable Energy | 4.6 kWh |
| Warranty | 10 years |
| Max Continuous Discharge Current | 100A |
| Cycle Life | 6000 cycles |
| Communication | CAN, RS485 |
| Operating Temperature (Charge) | 0°C to 55°C |
| Operating Temperature (Discharge) | -20°C to 55°C |
| Storage Temperature | -20°C to 45°C |
| Protection | Overcharge, Over-discharge, Over-current, Short circuit, Over-temperature, Low-temperature |
| Peak Discharge Current | 150A (5s) |