13
BLUE (-) Multiplex Input
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8
seconds will trigger full alarm sequence and report Zone 2.
RED (+) 12V Constant and BLACK (-) Ground
Do not use these for anything besides the plug-in shock sensor.
Programming Jumper
Light Flash Jumper
This jumper is used to determine the light flash output. In the (+) position, the on-board relay is
enabled and the unit will output (+)12V on the WHITE wire, H1/2. In the (-) position, the on-
board relay is disabled. The WHITE wire, H1/2, will supply a 200 mA (-) output suitable for
driving factory parking light relays.
NOTE: For parking light circuits that draw 10 amps or more, the jumper must be switched to a (-)
light flash output. P/N 8617 or a standard automotive SPDT relay must be used on the H1/2 light
flash output harness wire.
IMPORTANT! DO NOT connect the H1/2 light flash wire to a negative vehicle light
flash wire before changing the programming jumper to the negative polarity position or
damage to vehicle light circuit may occur.