CLEANING AND CARE
Warning: Make sure the heaer is in off position and is cool!
Warning: Do not clean heater with cleaners that are combustible or corrosive.
Wipe off powder coated surfaces with soft, moist rag and soap water.
Remove debris, spider and insect nests from ventilation opening of the cylin-
der enclosure, control compartment, burner and circulation air passageways
of the heater with heavy duty pipe cleaner or compressed air to keep appli-
ance clean and safe for use.
Never clear ports or other openings with toothpic.ks or other article that will
break and block the ports.
If carbon deposits develop, remove the reflector and flame screen and clean
them with soap water.
Do not paint the flame screen, control panel or reflector.
Cover the burner unit with the optional supplied protective cover when the
heater is not in use. Wait until the heater is cool before covering.
In a salt-air environment, such as near an ocean, corrosion occurs more
quickly than normal. Check frequently for corroded areas and repair them
promptly.
TROUBLESHOOTING
Review these tips first and you may not need to call for service.
Problem Probable cause Solution
Pilot will not light
Gas valve may be OFF Turn the gas valve ON.
Tank fuel empty Refill gas tank.
Pilot injector blocked Clean or replace pilot injec-
tor.
Air in supply system Purge air from lines by pres-
sing the control knob until
you smell gas.
Loose connections Check all fittings.
Low gas pressure Replace cylinder with a new
cylinder.
Battery is empty Replace battery with a full
battery
Pilot will not stay on
Lack of fuel pressure Keep the variable knob
depressed for 10-20 seconds
or more after the pilot light
ignited.
Tank near empty. Refill gas
tank.
Debris around pilot Clean dirty area.
Loose connections Tighten connections.
Thermocouple bad Replace thermocouple.
Gas Ieak in Iine Check connections.