The QSC DataPort-equipped amplifiers connected to the BASIS 914lz must have their power switches in the “on” position. For initial
testing, use the lowest useful gain setting until the system is operating as expected. After the system setup has been verified and
tested, gain settings may be adjusted as required.
Network
The network should be operable and QSControl.net software should be installed/running on the system controller computer.
CobraNet Connection Loss
If you are operating with a valid CobraNet network, and the connection to the network is disrupted, audio will momentarily mute, allow-
ing the BASIS 914lz to synchronize with its internal clock. If CobraNet network connection is re-established, the audio will mute again
while the BASIS 914lz synchronizes with CobraNet.
Configuration Memories
The BASIS 914lz has non-volatile storage locations that contain settings for the device as well as DSP signal flow. The storage loca-
tions make it possible to set up the BASIS for different situations and quickly recall the setup with or without QSControl.net software
using the front panel controls.