EasyManua.ls Logo

QSC BASIS 922az User Manual

QSC BASIS 922az
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
EN
1
TD-000133-00 rev.B
EN
*TD-000133-00*
BASIS 922az
8x8 CobraNet Enabled Control and Monitoring Signal Processor
Hardware Manual
Question and Answer IconNeed help?

Do you have a question about the QSC BASIS 922az and is the answer not in the manual?

QSC BASIS 922az Specifications

General IconGeneral
CategoryComputer Hardware
Mic/Line Inputs22 balanced
Phantom PowerYes
AECYes
RAM4 GB
Storage64 GB SSD
Operating SystemLinux
GraphicsIntegrated Intel HD Graphics
WirelessNo
ProcessorIntel Celeron

Summary

Safety Precautions and Symbols

General Safeguards and Warnings

Safety instructions for electrical hazards and proper unit use.

Lithium Battery Hazard Warning

Warning about potential hazards of the non-rechargeable lithium battery.

FCC Interference Compliance

Statement regarding FCC rules and potential radio frequency interference.

Introduction to BASIS 922az

System Integration and Control Overview

How the BASIS 922az integrates amplifiers and speakers with QSControl.net.

Digital Signal Processing Engine

Overview of the configurable DSP engine for audio processing.

BASIS 922az Technical Details

Audio Latency and CobraNet Features

Details on processing latency and low-latency CobraNet support.

Block Diagram Explanation

Visual representation of the unit's internal signal flow and connectivity.

Networking the BASIS 922az

Network Interface Modes (Single vs. Two-Wire)

Explains Single-Wire and Two-Wire network interface configurations.

CobraNet Network Requirements

Guidelines for ensuring reliable CobraNet data transmission.

Network Design and Connectivity

Network Topology Best Practices

Recommendations for using switches versus repeaters in network design.

QSControl.net Direct Connection Example

Example of a simple crossover cable setup for QSControl.net.

Network Connection Examples

CobraNet Direct Connection Example

Example of connecting two BASIS units directly via CobraNet.

Network Configuration Examples

Single Wire Interface Setup

Illustrates using one CAT-5 cable for both audio and control data.

Advanced Network Configurations

Two-Wire Interface with VLANs

Using VLANs on a managed switch for separate audio and control networks.

Network Topology Options

Two-Wire Interface with Separate Switches

Using dedicated switches for audio and control for improved fault tolerance.

Product Setup and Mounting

Unpacking and Included Components

List of items included in the package and unpacking advice.

Rack and Non-Rack Mounting Instructions

Instructions for physically installing the BASIS 922az unit.

Software Installation and Management

QSControl.net Software Installation

Step-by-step guide for installing the QSControl.net software.

Uninstalling QSControl.net Software

Procedures for removing the QSControl.net software from the system.

General Information and Configuration

Amplifier and Network Initial Setup

Initial setup steps for amplifiers and network connectivity.

CobraNet Connection Loss Handling

Behavior during CobraNet network disconnections and reconnections.

Configuration Memory Usage

How to save and recall device settings and DSP configurations.

Physical Connections

Power and Network Cable Connections

Connecting AC power, CobraNet, and QSControl network cables.

Analog and Digital I/O Wiring

Wiring for analog inputs, Omni In, Logic Out, and Relay Out.

Input/Output and Indicators

Monitor Chain and RS-232 Port Connections

Connections for monitor chain signals and RS-232 serial communication.

DataPort Connections Explained

Information on connecting QSC DataPort devices to the unit.

Front Panel LED Indicator Guide

Explanation of the POWER, DIAGNOSTIC, and network status LEDs.

Front Panel Interface Operation

Network Status LEDs and Port Indicators

Detailed meaning of QSControl, CobraNet, and DataPort indicator lights.

LCD Display and Control Navigation

How to navigate and interact with the unit's LCD screen and buttons.

Front Panel Password Security

Setting up and using password lockout for front panel editing.

LCD Navigation Map

Main and Utility Menu Navigation

Overview of screen-dependent button functions and menu flows.

Password and Custom Menu Access

Navigating password entry and custom user menu options.

Getting Started with BASIS 922az

Initial Connection and Software Setup

Steps for physically connecting the BASIS and installing QSControl.net.

QSControl.net Device Integration

Adding and Configuring the BASIS Device

Integrating the BASIS 922az into the QSControl.net inventory.

Software Operation and Help Resources

Guidance on using QSControl.net and accessing its help documentation.

Operation and Network Protocols

QSControl and CobraNet Port Functionality

How the QSControl and CobraNet ports operate over Ethernet.

CobraNet Channel and Resolution Details

Specifications for CobraNet channel density and audio resolution.

CobraNet Interface Modes

Explanation of Single-wire and Two-wire interface concepts.

Runtime Configuration Storage

How the scratchpad feature saves runtime configuration changes.

Utility and Diagnostic Functions

Reset Switch Usage and Recovery

Procedure for using the reset switch for troubleshooting.

RS-232 Serial Port for Diagnostics

Using the RS-232 port for system health and settings access.

RS-232 Communication Procedures

HyperTerminal Setup for RS-232

Step-by-step guide for establishing RS-232 communication via HyperTerminal.

IP Address Assignment Guidelines

Important notes on setting IP addresses for network communication.

Telnet Access for Diagnostics

Telnet Session Establishment

How to open a Telnet session for accessing RS-232 features.

Preliminary Specifications - Audio Performance

Dynamic Range, Distortion, and Crosstalk

Technical audio performance metrics like dynamic range and distortion.

Frequency Response and Input Specs

Electrical input characteristics and frequency response data.

Latency and Channel Specifications

Delay times and audio channel processing details.

Connector and Cable Specifications

Details on DataPort and terminal block connector types and cables.

Preliminary Specifications - Interfaces and Indicators

Monitor, Relay, Logic, and Omni I/O Specs

Specifications for monitoring, relay, logic, and omni input connections.

Communication Ports and Indicators

Details on RS-232, QSControl, CobraNet ports and status indicators.

Contact and Warranty Information

QSC Contact Details

Mailing address, phone numbers, and web resources for QSC.

Warranty and Disclaimer Information

Product warranty terms and a disclaimer on network integration risks.