16
BLAST/REV D/OCTOBER 2002
Quantum Blast
Flashing
Bars Diagnosis Solution
10 Green High Battery Voltage Check Batteries
9 Green Solenoid Brake Fault Check Motor/Brake Wiring
8 Green Possible Controller Fault See Authorised Pride Provider
7 Yellow Possible Joystick Fault See Authorised Pride Provider
6 Yellow Inhibit Active Unplug Charger/Check Connections
5 Yellow Right Motor Wiring Fault Check Right Motor Wiring
4 Yellow Right Motor Disconnected Check Right Motor Wiring
3 Red Left Motor Wiring Fault Check Left Motor Wiring
2 Red Left Motor Disconnected Check Left Motor Wiring
1 Red Low Battery Voltage Check Batteries/Battery Wiring
If you cannot resolve your problem, see your authorised Pride provider.
REMOTE PLUS OPTIONAL FEATURES
See figure 9 to reference the following optional features:
l Light Key: If your Blast is equipped with the deluxe lighting package, the light key activates the lights.
l Turn Indicator Keys: The arrow keys activate the turn indicators regardless of whether or not your Blast is powered off
or on.
l Hazard Warning Key: This key operates the hazard lights.
CONTROLLER FOLDBACK
The Remote Plus controller is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors and
the controller. In the event that the motors or the controller become excessively hot (above 50C/122F), the controller
reduces the motor voltage. For every degree above 50C/122F, the controller reduces the voltage by 5 volts. This reduces
your Blastís speed and allows the electrical components to cool down. When the temperature returns to a safe level, your
Blast resumes its normal speed.
TROUBLE CODES
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems
with your Blast. The battery condition meter has ten individual bars. The bars provide information by the number of bars that
are flashing. If the meter is flashing rapidly, the controller may be indicating a fault. For instance, the very first red bar flashing
rapidly indicates the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly
flashing meter lights.
REMOTE PLUS CONTROLLER