Quattroflow
Installation,
Operation &
Troubleshooting
Guide
Version: Rev. 0 (July 2017)

Questions and Answers

  • K
    Kelsey LewisSep 1, 2025
    What to do if Quattroflow QF1200 stopped by the thermal circuit breaker?
    • D
      Donald Montgomery DDSSep 1, 2025
      If your Quattroflow Water Pump has stopped due to the thermal circuit breaker, allow the motor to cool down and consider reducing the power consumption.
  • B
    Brandy JohnsonNov 10, 2025
    Why Quattroflow QF1200 does not start?
    • C
      Carol WhiteNov 10, 2025
      There are several reasons why your Quattroflow Water Pump might not be starting: * Check the power supply and cables. * Ensure the front screws of the pump chamber/pressure plate are tightened to the defined torque. * Verify suction pipeline and TC-seals for tightness. * Confirm the correct flow direction as indicated by the arrow on the pump; if incorrect, turn the pump head. * Make sure that there are no foreign bodies in pump. * The diameters of the pipes in suction or pressure line are too small, which poses a risk for cavitation. * Check viscosity of liquid pumped. * Avoid air inclusions in the liquid to be pumped. * Open valve in discharge line completely, remove obstruction in discharge line to check pressure head. * Check the coupling halves, they must be fixed...
  • D
    davidharrisNov 19, 2025
    What to do if Quattroflow QF1200 does not start?
    • B
      Billy OwenNov 19, 2025
      If your Quattroflow Water Pump isn't starting, consider these potential causes and solutions: * The bearings might be worn or defective and must be replaced. * The valves could be dry, deformed, or worn; change the valve or wet the pump. * The diaphragm might be burst; replace it with the respective elastomer service-kit. * Defective O–rings between valve plate and pump housing; replace them with the respective elastomer service-kit. * The clamping ring screw got loose; fix it with the defined torque. * The parameters of the control panel are wrong; check basic settings. * Pump may not start in manual mode if configured for remote operation, so check parameter settings. * If the pump cooled down too fast after SIP, allow slow cooling with room temperature. * Check chemic...