EasyManua.ls Logo

Quattroflow QF1200 - Priming

Quattroflow QF1200
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quattroflow Installation, Operation & Troubleshooting Guide
Rev. 0
Page 13 of 25 www.quattroflow.com
5.4 Priming
Quattroflow pumps are self-priming and can run dry (no use of mechanical seals).
Please note that the pump needs to be properly primed in order to achieve a stable flow and low pulsation. A
minimum flow rate is required for the priming (complete removal from air inside the pump chamber). The
following table indicates the minimum required pump speed for water with <0.5 bar discharge pressure.
Please note that these values may depend on the installation. The duration of the vent process at a given
min. pump speed is generally from 5 to 10 seconds.
Pump size /
eccentric shaft
Min. pump speed for
self-venting at free output
Min. flow rate for
self-venting at free output
QF150 /
ca. 1000 rpm
ca. 75 l/h
QF1200 /
(Standard)
ca. 500 rpm
ca. 300 l/h
QF1200 / 3°
ca. 900 rpm
ca. 300 l/h
QF4400 / QF5050 / 6°
(Standard)
ca. 500 rpm
ca. 3.200 l/h
QF4400 / QF5050 / 3°
ca. 700 rpm (ca. 80 sec.)
ca. 2250 l/h (ca. 80 sec.)
QF20K / 7°
ca. 150 rpm
ca. 4.000 l/h
Table 4 Minimum pump speed and flow rate for self-venting at free output (Water @ RT)
The following table shows the suction high for each pump size. Please note that these values may depend on
the installation.
Pump size /
eccentric shaft
Pump speed
Suction lift (dry)
QF150 / 5°
3000 rpm
2,0 3,0 m
QF1200 / 5°
(Standard)
1800 rpm
4,0 4,5 m
QF1200 / 3°
1800rpm
2,5 3,0 m
QF4400 / QF5050 / 6°
(Standard)
1200 rpm
4,0 4,5 m
QF4400 / QF5050 / 3°
1200 rpm
2,5 3,0 m
QF20K / 7°
780 rpm
4,0 4,5 m
Table 5 Suction high and respective pump speed (Water @ RT)