Quattroflow Installation, Operation & Troubleshooting Guide
Rev. 0
Page 13 of 25 www.quattroflow.com
5.4 Priming
Quattroflow pumps are self-priming and can run dry (no use of mechanical seals).
Please note that the pump needs to be properly primed in order to achieve a stable flow and low pulsation. A
minimum flow rate is required for the priming (complete removal from air inside the pump chamber). The
following table indicates the minimum required pump speed for water with <0.5 bar discharge pressure.
Please note that these values may depend on the installation. The duration of the vent process at a given
min. pump speed is generally from 5 to 10 seconds.
Pump size /
eccentric shaft
Min. pump speed for
self-venting at free output
Min. flow rate for
self-venting at free output
QF4400 / QF5050 / 6°
(Standard)
ca. 700 rpm (ca. 80 sec.)
ca. 2250 l/h (ca. 80 sec.)
Table 4 Minimum pump speed and flow rate for self-venting at free output (Water @ RT)
The following table shows the suction high for each pump size. Please note that these values may depend on
the installation.
Pump size /
eccentric shaft
QF4400 / QF5050 / 6°
(Standard)
Table 5 Suction high and respective pump speed (Water @ RT)