• Group 4: Basic on/off (Triggered at sensing moving direction of roller: up= FF, down = 00)
up to 16 nodes.
When blinds are moving up, Flush Shutter DC will send Basic set ON command to
associated device and associated device will turn ON. When blinds are moving down,
Flush Shutter DC will send Basic set OFF command to associated device and the device
will turn OFF.
• Group 5: Basic on/off (Triggered at reaching roller position: bottom=FF, top=0) up to 16
nodes.
When blinds reach upper position Flush Shutter DC will send Basic set OFF command to
associated device and the device will turn OFF. When blinds reach down position Flush
Shutter DC will send Basic set ON command to associated device and the device will turn
ON.
• Group 6: Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0) up
to 16 nodes
When blinds reach down position, Flush Shutter DC will send Basic set ON command and
the device will turn ON. When blinds are in any position which is not down (0 %) Flush
Shutter DC will send Basic set OFF to associated device and the device will turn OFF.
• Group 7: Multilevel set (Triggered at change of value of the Flush Shutter DC position), up
to 16 nodes.
Flush shutter DC will set Switch multilevel command to associated device, the command
is actual position of blinds so the associated device will turn on same level as blinds are.
Example with association between Flush Shutter DC and dimmer, when shutters blinds
reach middle position 50 % it will send switch multilevel set 50 % command and dimmer
will turn on 50 %.