Keeping the push-button pressed (for time > (full turn slates time) connected to I1 (up), initiates
up movement, until the push-button is released.
Slates on end position - 180 degree
Clicking the push-button connected to I1 (up), initiates Shutter up movement, until the push-
button is clicked again.
Clicking the push-button connected to I2 (down), initiates down movement, until the push-
button is clicked again.
If the Shutter is moving, any click (of any push-button), will stop the movement.
Keeping the push-button (for time > full turn slates time-par.72), connected to I1 (up), pressed,
initiates the initiates slates turning towards start - 180 degree position, until the push-button is
released.
Keeping the push-button (for time > full turn slates time-par.72), connected to I2 (down),
pressed, initiates full slates turn and down movement, until the push-button is released.
Keeping the push-button (for time > (full turn slates time), connected to I2 (down), pressed,
initiates down movement, until push-button is released.