EN.
50
Parameter no. 85 Power consumption max delay time
Define the maximum time before the power consumption of the motor, after one of the relays is
switched ON, is read from the device. If there is no power consumption during the set time
(motor not connected, damaged or requires longer time to start, motor at the end position), the
relay will switch OFF. This time is defined by entering it manually.
Values (size is 1-byte dec):
default value 8 = 800 ms
0 = time is set automatically
3 - 50 = 0.3seconds - 5seconds (100ms resolution)
Parameter no. 86 Power consumption at limit switch delay time
This parameter defines the maximum time after which the active output will switch off, due to
reaching a limit switch. When power consumption is below the specified power threshold,
defined in the parameter no. 76, the set time duration will have to pass in order for the output
to turn off.
Values (size is 1-byte dec):
default value 8 = 800 ms
3 - 50 = 0.3 seconds 5 seconds (100ms resolution)